Transceiver Performance Monitoring

Transceiver Performance Monitoring Overview

The Transceiver Performance Monitoring and Enhanced Diagnostics enables viewing the Digital Optical Monitoring (DOM) parameters for the optics that support enhanced diagnostics. Use the show commands to view the instantaneous values for various PAM4 parameters such as Signal-To-Noise Ratio, Residual Inter Symbol Interference, PAM4 Level Transition Parameters, and other parameters supported on optics interfaces.

Using the Performance Monitoring feature allows EOS to collect and maintain certain performance statistics over a user-defined time. EOS stores data for two intervals: the current interval and the most recently completed interval. When the current interval ends, the data is saved as the previous interval so a new current interval can start, and the old previous interval data discarded.

Configuring Transceiver Performance Monitoring

EOS enables the Digital Optical Monitoring (DOM) on all interfaces and you cannot disable the feature.

EOS disables Performance Monitoring on all interfaces by default. Use the performance-monitoring transceiver default configuration command to enable Performance Monitoring on all interfaces across the system.
switch(config)#performance-monitoring transceiver default
Enable Performance Monitoring on a per interface basis using the performance-monitoring transceiver configuration command.
switch(config)#interface Ethernet8/1
switch(config-if-Et8/1)#performance-monitoring transceiver
Configure the Performance Monitoring period using the performance-monitoring period <period> configuration command.
switch(config)#performance-monitoring period 60s

Thecommand configures the performance monitoring period to 60 seconds across the system. This command supports configuring the performance monitoring period in units of either seconds, minutes, hours or days. For example, use performance-monitoring period 30 minutes to configure the period as 30 minutes, performance-monitoring period 2 hours to configure the period as 2 hours and so on. The default performance-monitoring period is 15 minutes.

Use the no form of these commands to revert the configuration.

100GBASE-FR, 100GBASE-LR and 100GBASE-DR do not have thresholds for enhanced Digital Optical Monitoring (DOM) parameters, so these parameters and their thresholds do not display in the output of show interfaces transceiver dom thresholds command.

switch# show interfaces Ethernet8/1 transceiver dom thresholds 
Ch: Channel, mA: milliamperes, dBm: decibels (milliwatts),
C: Celsius, V: Volts, NA or N/A: not applicable.
                                                            
Ethernet8/1
Last update: 0:00:02 ago
                                     High Alarm  High Warn   Low Warn  Low Alarm
Parameter             Ch      Value  Threshold  Threshold  Threshold  Threshold Unit    Indicator
-------------------------------------------------------------------------------------------------
Temperature            -      58.87      72.00      65.00       5.00      -2.00 C
Voltage                -       3.28       3.56       3.47       3.14       3.04 V
TX bias current        1      83.90     131.00     120.00      35.00      30.00 mA
                       2      85.30     131.00     120.00      35.00      30.00 mA
Optical TX power       1     -10.51      -6.99      -8.00     -11.00     -12.00 dBm
                       2      -9.70      -6.99      -8.00     -11.00     -12.00 dBm
Optical RX power       1      -0.99       6.99       6.02      -2.00      -3.01 dBm

Transceiver Performance Monitoring

100GBASE-FR, 100GBASE-LR and 100GBASE-DR do not have thresholds of enhanced Digital Optical Monitoring (DOM) parameters, so these parameters and thresholds do not display in the output of CLI command show interfaces transceiver dom thresholds.

switch# show interfaces Ethernet8/1 transceiver dom thresholds 
Ch: Channel, mA: milliamperes, dBm: decibels (milliwatts),
C: Celsius, V: Volts, NA or N/A: not applicable.

Ethernet8/1
Last update: 0:00:02 ago
                                    High Alarm  High Warn   Low Warn  Low Alarm
Parameter             Ch      Value  Threshold  Threshold  Threshold  Threshold Unit    Indicator
-------------------------------------------------------------------------------------------------
Temperature            -      58.87      72.00      65.00       5.00      -2.00 C
Voltage                -       3.28       3.56       3.47       3.14       3.04 V
TX bias current        1      83.90     131.00     120.00      35.00      30.00 mA
                       2      85.30     131.00     120.00      35.00      30.00 mA
Optical TX power       1     -10.51      -6.99      -8.00     -11.00     -12.00 dBm
                       2      -9.70      -6.99      -8.00     -11.00     -12.00 dBm
                       Optical RX power       1      -0.99       6.99       6.02      -2.00      -3.01 dBm

DisplayingTransceiver Performance Monitoring

Use the show interfaces transceiver dom command to display the Digital Optical Monitoring (DOM) parameters. The displayed parameters are the most recently read, instantaneous values.

switch#show interfaces Ethernet8/1 transceiver dom
Ch: Channel, N/A: not applicable, TX: transmit, RX: receive
mA: milliamperes, dBm: decibels (milliwatts), C: Celsius, V: Volts

Ethernet8/1
Last update: 0:00:03 ago
Parameter             Ch     Value Unit
-------------------------------------------
Temperature            -     58.97 C
Voltage                -      3.28 V
TX bias current        1     83.61 mA
                       2     85.15 mA
Optical TX power       1    -10.60 dBm
                       2     -9.79 dBm
Optical RX power       1     -0.84 dBm
                       2     -2.28 dBm
SNR                    1     17.46 dB
                       2     15.89 dB
Residual ISI           1      0.00 ps/nm
                       2      0.00 ps/nm
Level transitions      1    829.00
                       2   3055.00
TEC current error      1   -527.60 mA
                       2   -365.70 mA
Frequency error        1     -0.48 GHz
                       2      0.00 GHz
Pre-FEC BER            -  1.53e-03
Uncorrected BER        -  0.00e+00

Use the show interfaces transceiver dom thresholds command to display the Digital Optical Monitoring (DOM) parameters and thresholds. The displayed parameters are the most recently read, instantaneous values.

switch#show interfaces Ethernet8/1 transceiver dom thresholds 
Ch: Channel, mA: milliamperes, dBm: decibels (milliwatts),
C: Celsius, V: Volts, NA or N/A: not applicable.

Ethernet8/1
Last update: 0:00:02 ago
                                    High Alarm  High Warn   Low Warn  Low Alarm
Parameter             Ch      Value  Threshold  Threshold  Threshold  Threshold Unit    Indicator
-------------------------------------------------------------------------------------------------
Temperature            -      58.87      72.00      65.00       5.00      -2.00 C
Voltage                -       3.28       3.56       3.47       3.14       3.04 V
TX bias current        1      83.90     131.00     120.00      35.00      30.00 mA
                       2      85.30     131.00     120.00      35.00      30.00 mA
Optical TX power       1     -10.51      -6.99      -8.00     -11.00     -12.00 dBm
                       2      -9.70      -6.99      -8.00     -11.00     -12.00 dBm
Optical RX power       1      -0.99       6.99       6.02      -2.00      -3.01 dBm
                       2      -2.45       6.99       6.02      -2.00      -3.01 dBm          WARN
SNR                    1      17.46      40.00      39.00      19.00      18.00 dB          ALARM
                       2      15.89      40.00      39.00      19.00      18.00 dB          ALARM
Residual ISI           1       0.00     409.60     128.00    -128.00    -409.60 ps/nm
                       2       0.00     409.60     128.00    -128.00    -409.60 ps/nm
Level transitions      1     812.00   57344.00   53248.00       0.00       0.00
                       2    3249.00   57344.00   53248.00       0.00       0.00
TEC current error      1    -504.70     409.60     128.00    -128.00    -409.60 mA          ALARM
                       2    -329.50     409.60     128.00    -128.00    -409.60 mA           WARN
Frequency error        1      -0.42       5.12       2.56      -2.56      -5.12 GHz
                       2      -0.06       5.12       2.56      -2.56      -5.12 GHz
Pre-FEC BER            -   1.47e-03   1.00e-04   1.00e-05        N/A        N/A             ALARM
Uncorrected BER        -   0.00e+00   0.00e+00   0.00e+00        N/A        N/A

The Indicator column in the output above gives an indication of where the value lies with respect to its thresholds. Nothing is shown when the parameter is in the expected range between the Low Warn and High Warn thresholds. If the value is greater than or equal to the High Alarm or less than or equal to the Low Alarm, ALARM is shown. If the value is greater than or equal to the High Warn (but less than the High Alarm) or less than or equal to the Low Warn (but greater than the Low Alarm), WARN is shown.

The show interfaces transceiver performance-monitoring command is used to display the performance monitoring statistics from the CLI. This command will display data only if the feature has been enabled using the configuration command performance-monitoring transceiver as described in the Configuration section.

switch#show interfaces Ethernet8/1 transceiver performance-monitoring
Ch: Channel, N/A: not applicable

Performance monitoring period : 0:15:00
Ethernet8/1
Parameter                                     Ch        Value
-------------------------------------------------------------
Current Interval 0
  Started                                      -  0:00:12 ago
  Last update                                  -  0:00:02 ago
  Pre-FEC BER avg                              -     1.41e-03
  Pre-FEC BER high alarm exceeded              -            0
  Pre-FEC BER high warn exceeded               -            0
  Pre-FEC BER max                              -     1.54e-03
  Pre-FEC BER min                              -     5.93e-06
  Temperature alarm exceeded                   -            0
  Temperature warn exceeded                    -            0
  Uncorrected BER avg                          -     0.00e+00
  Uncorrected BER high alarm exceeded          -            0
  Uncorrected BER high warn exceeded           -            0
  Uncorrected BER max                          -     0.00e+00
  Uncorrected BER min                          -     0.00e+00
Interval 1
  Started                                      -  0:15:13 ago
  Last update                                  -  0:00:12 ago
  Pre-FEC BER avg                              -     1.53e-03
  Pre-FEC BER high alarm exceeded              -            0
  Pre-FEC BER high warn exceeded               -            0
  Pre-FEC BER max                              -     1.74e-03
  Pre-FEC BER min                              -     3.11e-05
  Temperature alarm exceeded                   -            0
  Temperature warn exceeded                    -            0
  Uncorrected BER avg                          -     0.00e+00
  Uncorrected BER high alarm exceeded          -            0
  Uncorrected BER high warn exceeded           -            0
  Uncorrected BER max                          -     0.00e+00
  Uncorrected BER min                          -     0.00e+00

Performance Monitoring Period: 0:15:00

This indicates the length of one Performance Monitoring period. 0:15:00 specifies a period of 15 minutes, which is the default value for this parameter. The Performance Monitoring period can be configured using the performance-monitoring period configuration command as described in the Configuration section.

Started: 0:00:12 ago

Indicates the time the host started the performance monitoring interval.

Last Update: 0:00:02 ago

Indicates the last time the host read the diagnostic parameters from the module. The host samples values every six seconds.

Pre-FEC BER avg, Uncorrected BER avg

The average value so far in the indicated performance monitoring interval.

Pre-FEC BER min, Uncorrected BER min

The minimum value so far in the indicated performance monitoring interval.

Pre-FEC BER max, Uncorrected BER max

The maximum value so far in the indicated performance monitoring interval.

Pre-FEC BER high warn exceeded, Uncorrected BER high warn exceeded, Pre-FEC BER high alarm exceeded, Uncorrected BER high alarm exceeded

The number of times the host read a value which was greater than the indicated threshold. The host reads values and checks exceeded thresholds every six seconds. This provides only an indication of the actual exceeded count.

Temperature warn exceeded, Temperature alarm exceeded

The number of times the host read a value which was outside the range of the indicated threshold. The host reads values and checks exceeded thresholds every six seconds. Please note that this provides only an indication of the actual exceeded count.

The show interfaces transceiver performance-monitoring thresholds command displays the performance monitoring statistics and their thresholds from the CLI. This command only displays data only if the feature has been enabled using the configuration command performance-monitoring transceiver.

switch# show interfaces Ethernet8/1 transceiver performance-monitoring thresholds 
Ch: Channel, N/A: not applicable

Performance monitoring period : 0:00:30

Ethernet8/1
                                                              High Alarm  High Warn   Low Warn  Low Alarm
Parameter                                     Ch        Value  Threshold  Threshold  Threshold  Threshold Indicator
--------------------------------------------------------------------------------------------------------------------
Current Interval 0
  Started                                      -  0:00:26 ago
  Last update                                  -  0:00:03 ago
  Pre-FEC BER avg                              -     1.41e-03   1.00e-04   1.00e-05        N/A        N/A     ALARM
  Pre-FEC BER high alarm exceeded              -            0        N/A        N/A        N/A        N/A
  Pre-FEC BER high warn exceeded               -            0        N/A        N/A        N/A        N/A
  Pre-FEC BER max                              -     1.55e-03   1.00e-04   1.00e-05        N/A        N/A     ALARM
  Pre-FEC BER min                              -     5.93e-06   1.00e-04   1.00e-05        N/A        N/A
  Temperature alarm exceeded                   -            0        N/A        N/A        N/A        N/A
  Temperature warn exceeded                    -            0        N/A        N/A        N/A        N/A
  Uncorrected BER avg                          -     0.00e+00   0.00e+00   0.00e+00        N/A        N/A
  Uncorrected BER high alarm exceeded          -            0        N/A        N/A        N/A        N/A
  Uncorrected BER high warn exceeded           -            0        N/A        N/A        N/A        N/A
  Uncorrected BER max                          -     0.00e+00   0.00e+00   0.00e+00        N/A        N/A
  Uncorrected BER min                          -     0.00e+00   0.00e+00   0.00e+00        N/A        N/A
Interval 1
  Started                                      -  0:00:57 ago
  Last update                                  -  0:00:26 ago
  Pre-FEC BER avg                              -     1.53e-03   1.00e-04   1.00e-05        N/A        N/A     ALARM
  Pre-FEC BER high alarm exceeded              -            0        N/A        N/A        N/A        N/A
  Pre-FEC BER high warn exceeded               -            0        N/A        N/A        N/A        N/A
  Pre-FEC BER max                              -     1.74e-03   1.00e-04   1.00e-05        N/A        N/A     ALARM
  Pre-FEC BER min                              -     3.11e-05   1.00e-04   1.00e-05        N/A        N/A      WARN
  Temperature alarm exceeded                   -            0        N/A        N/A        N/A        N/A
  Temperature warn exceeded                    -            0        N/A        N/A        N/A        N/A
  Uncorrected BER avg                          -     0.00e+00   0.00e+00   0.00e+00        N/A        N/A
  Uncorrected BER high alarm exceeded          -            0        N/A        N/A        N/A        N/A
  Uncorrected BER high warn exceeded           -            0        N/A        N/A        N/A        N/A
  Uncorrected BER max                          -     0.00e+00   0.00e+00   0.00e+00        N/A        N/A
  Uncorrected BER min                          -     0.00e+00   0.00e+00   0.00e+00        N/A        N/A

Transceiver Performance Monitoring Commands

performance-monitoring period

The performance-monitoring period command configures Performance Monitoring Period across the system.

The no performance-monitoring period command removes the Performance Monitoring Period configuration from the running-config.

Command Mode

Global Configuration Mode

Command Syntax

performance-monitoring period period

no performance-monitoring period period

Parameter

period performance monitoring period in units of either seconds, minutes, hours or days. The default performance-monitoring period is 15 minutes.

Example

This command configures the performance monitoring period to 60 seconds across the system.
switch(config)# performance-monitoring period 60s

performance-monitoring transceiver

The performance-monitoring transceiver command enable Performance Monitoring on per interface basis.

The no performance-monitoring transceiver command removes the Performance Monitoring configuration from the running-config.

Command Mode

Interface Configuration Mode

Command Syntax

performance-monitoring transceiver

no performance-monitoring transceiver

Example

This command enables the Performance Monitoring on a per interface basis.
switch(config)#interface Ethernet8/1
switch(config-if-Et8/1)#performance-monitoring transceiver

performance-monitoring transceiver default

The performance-monitoring transceiver default command enable Performance Monitoring on all interfaces across the system.

The no performance-monitoring transceiver default command removes the Performance Monitoring configuration from the running-config.

Command Mode

Global Configuration Mode

Command Syntax

performance-monitoring transceiver default

no performance-monitoring transceiver default

Example

This command enables the Performance Monitoring on all interfaces across the system.
switch(config)# performance-monitoring transceiver default

show interfaces transceiver dom

The show interfaces transceiver dom command displays the Digital Optical Monitoring (DOM) parameters from the CLI. The displayed parameters are the most recently read, ‘instantaneous’ values.

Command Mode

Privileged EXEC

Command Syntax

show interfaces interface transceiver dom

Parameter

interface Ethernet interface name.

Example

This command displays the Digital Optical Monitoring (DOM) parameters.
switch#show interfaces Ethernet8/1 transceiver dom
Ch: Channel, N/A: not applicable, TX: transmit, RX: receive
mA: milliamperes, dBm: decibels (milliwatts), C: Celsius, V: Volts

Ethernet8/1
Last update: 0:00:03 ago
Parameter             Ch     Value Unit
-------------------------------------------
Temperature            -     58.97 C
Voltage                -      3.28 V
TX bias current        1     83.61 mA
                       2     85.15 mA
Optical TX power       1    -10.60 dBm
                       2     -9.79 dBm
Optical RX power       1     -0.84 dBm
                       2     -2.28 dBm
SNR                    1     17.46 dB
                       2     15.89 dB
Residual ISI           1      0.00 ps/nm
                       2      0.00 ps/nm
Level transitions      1    829.00
                       2   3055.00
TEC current error      1   -527.60 mA
                       2   -365.70 mA
Frequency error        1     -0.48 GHz
                       2      0.00 GHz
Pre-FEC BER            -  1.53e-03
Uncorrected BER        -  0.00e+00

show interfaces transceiver dom thresholds

The show interfaces transceiver dom thresholds command displays the Digital Optical Monitoring (DOM) parameters andthresholds.

Command Mode

Privileged EXEC

Command Syntax

show interfaces interface transceiver dom thresholds

Parameter

interface Ethernet interface name.

Example

This command displays the Digital Optical Monitoring (DOM) parameters and their thresholds.
switch#show interfaces Ethernet8/1 transceiver dom thresholds 
Ch: Channel, mA: milliamperes, dBm: decibels (milliwatts),
C: Celsius, V: Volts, NA or N/A: not applicable.

Ethernet8/1
Last update: 0:00:02 ago
                                    High Alarm  High Warn   Low Warn  Low Alarm
Parameter             Ch      Value  Threshold  Threshold  Threshold  Threshold Unit    Indicator
-------------------------------------------------------------------------------------------------
Temperature            -      58.87      72.00      65.00       5.00      -2.00 C
Voltage                -       3.28       3.56       3.47       3.14       3.04 V
TX bias current        1      83.90     131.00     120.00      35.00      30.00 mA
                       2      85.30     131.00     120.00      35.00      30.00 mA
Optical TX power       1     -10.51      -6.99      -8.00     -11.00     -12.00 dBm
                       2      -9.70      -6.99      -8.00     -11.00     -12.00 dBm
Optical RX power       1      -0.99       6.99       6.02      -2.00      -3.01 dBm
                       2      -2.45       6.99       6.02      -2.00      -3.01 dBm          WARN
SNR                    1      17.46      40.00      39.00      19.00      18.00 dB          ALARM
                       2      15.89      40.00      39.00      19.00      18.00 dB          ALARM
Residual ISI           1       0.00     409.60     128.00    -128.00    -409.60 ps/nm
                       2       0.00     409.60     128.00    -128.00    -409.60 ps/nm
Level transitions      1     812.00   57344.00   53248.00       0.00       0.00
                       2    3249.00   57344.00   53248.00       0.00       0.00
TEC current error      1    -504.70     409.60     128.00    -128.00    -409.60 mA          ALARM
                       2    -329.50     409.60     128.00    -128.00    -409.60 mA           WARN
Frequency error        1      -0.42       5.12       2.56      -2.56      -5.12 GHz
                       2      -0.06       5.12       2.56      -2.56      -5.12 GHz
Pre-FEC BER            -   1.47e-03   1.00e-04   1.00e-05        N/A        N/A             ALARM
Uncorrected BER        -   0.00e+00   0.00e+00   0.00e+00        N/A        N/A

Command Output

The Indicator column in the output above gives an indication of where the value lies with respect to its thresholds. Nothing is shown when the parameter is in the expected range between the Low Warn and High Warn thresholds. If the value is greater than or equal to the High Alarm or less than or equal to the Low Alarm, ALARM is shown. If the value is greater than or equal to the High Warn (but less than the High Alarm) or less than or equal to the Low Warn (but greater than the Low Alarm), WARN is shown.

show interfaces transceiver performance-monitoring

The show interfaces transceiver performance-monitoring command displays the performance monitoring statistics from the CLI. This command will display data only if the Performance Monitoring has been enabled using the configuration command performance-monitoring transceiver.

Command Mode

Privileged EXEC

Command Syntax

show interfaces interface transceiver performance-monitoring

Parameter

INTERFACE Ethernet interface name.

Example

This command displays the performance monitoring statistics from the CLI.
switch# show interfaces Ethernet8/1 transceiver performance-monitoring
Ch: Channel, N/A: not applicable

Performance monitoring period : 0:15:00
Ethernet8/1
Parameter                                     Ch        Value
-------------------------------------------------------------
Current Interval 0
  Started                                      -  0:00:12 ago
  Last update                                  -  0:00:02 ago
  Pre-FEC BER avg                              -     1.41e-03
  Pre-FEC BER high alarm exceeded              -            0
  Pre-FEC BER high warn exceeded               -            0
  Pre-FEC BER max                              -     1.54e-03
  Pre-FEC BER min                              -     5.93e-06
  Temperature alarm exceeded                   -            0
  Temperature warn exceeded                    -            0
  Uncorrected BER avg                          -     0.00e+00
  Uncorrected BER high alarm exceeded          -            0
  Uncorrected BER high warn exceeded           -            0
  Uncorrected BER max                          -     0.00e+00
  Uncorrected BER min                          -     0.00e+00
Interval 1
  Started                                      -  0:15:13 ago
  Last update                                  -  0:00:12 ago
  Pre-FEC BER avg                              -     1.53e-03
  Pre-FEC BER high alarm exceeded              -            0
  Pre-FEC BER high warn exceeded               -            0
  Pre-FEC BER max                              -     1.74e-03
  Pre-FEC BER min                              -     3.11e-05
  Temperature alarm exceeded                   -            0
  Temperature warn exceeded                    -            0
  Uncorrected BER avg                          -     0.00e+00
  Uncorrected BER high alarm exceeded          -            0
  Uncorrected BER high warn exceeded           -            0
  Uncorrected BER max                          -     0.00e+00
  Uncorrected BER min                          -     0.00e+00

Command Output

Performance Monitoring Period: 0:15:00

This indicates the length of one Performance Monitoring period. 0:15:00 specifies a period of 15 minutes, which is the default value for this parameter. The Performance Monitoring period can be configured using the performance-monitoring period configuration command as described in the Configuration section.

Started: 0:00:12 ago

This indicates the time the host started the performance monitoring interval.

Last Update: 0:00:02 ago

This indicates the last time the host read the diagnostic parameters from the module. The host samples values every six seconds.

Pre-FEC BER avg, Uncorrected BER avg

This is the average value so far in the indicated performance monitoring interval.

Pre-FEC BER min, Uncorrected BER min

This is the minimum value so far in the indicated performance monitoring interval.

Pre-FEC BER max, Uncorrected BER max

This is the maximum value so far in the indicated performance monitoring interval.

Pre-FEC BER high warn exceeded, Uncorrected BER high warn exceeded, Pre-FEC BER high alarm exceeded, Uncorrected BER high alarm exceeded

This is the number of times the host read a value which was greater than the indicated threshold. The host reads values and checks exceeded thresholds every 6 seconds. Please note that this provides only an indication of the actual exceeded count.

Temperature warn exceeded, Temperature alarm exceeded

This is the number of times the host read a value which was outside the range of the indicated threshold. The host reads values and checks exceeded thresholds every six seconds. Note that this provides only an indication of the actual exceeded count.

show interfaces transceiver performance-monitoring thresholds

The show interfaces transceiver performance-monitoring thresholds command displays the performance monitoring statistics and their thresholds from the CLI.

Command Mode

Privileged EXEC

Command Syntax

show interfaces INTERFACE transceiver performance-monitoring thresholds

Parameter

INTERFACE Ethernet interface name.

Example

This command displays the performance monitoring statistics and their thresholds from the CLI.
switch# show interfaces Ethernet8/1 transceiver performance-monitoring thresholds 
Ch: Channel, N/A: not applicable

Performance monitoring period : 0:00:30

Ethernet8/1
                                                              High Alarm  High Warn   Low Warn  Low Alarm
Parameter                                     Ch        Value  Threshold  Threshold  Threshold  Threshold Indicator
--------------------------------------------------------------------------------------------------------------------
Current Interval 0
  Started                                      -  0:00:26 ago
  Last update                                  -  0:00:03 ago
  Pre-FEC BER avg                              -     1.41e-03   1.00e-04   1.00e-05        N/A        N/A     ALARM
  Pre-FEC BER high alarm exceeded              -            0        N/A        N/A        N/A        N/A
  Pre-FEC BER high warn exceeded               -            0        N/A        N/A        N/A        N/A
  Pre-FEC BER max                              -     1.55e-03   1.00e-04   1.00e-05        N/A        N/A     ALARM
  Pre-FEC BER min                              -     5.93e-06   1.00e-04   1.00e-05        N/A        N/A
  Temperature alarm exceeded                   -            0        N/A        N/A        N/A        N/A
  Temperature warn exceeded                    -            0        N/A        N/A        N/A        N/A
  Uncorrected BER avg                          -     0.00e+00   0.00e+00   0.00e+00        N/A        N/A
  Uncorrected BER high alarm exceeded          -            0        N/A        N/A        N/A        N/A
  Uncorrected BER high warn exceeded           -            0        N/A        N/A        N/A        N/A
  Uncorrected BER max                          -     0.00e+00   0.00e+00   0.00e+00        N/A        N/A
  Uncorrected BER min                          -     0.00e+00   0.00e+00   0.00e+00        N/A        N/A
Interval 1
  Started                                      -  0:00:57 ago
  Last update                                  -  0:00:26 ago
  Pre-FEC BER avg                              -     1.53e-03   1.00e-04   1.00e-05        N/A        N/A     ALARM
  Pre-FEC BER high alarm exceeded              -            0        N/A        N/A        N/A        N/A
  Pre-FEC BER high warn exceeded               -            0        N/A        N/A        N/A        N/A
  Pre-FEC BER max                              -     1.74e-03   1.00e-04   1.00e-05        N/A        N/A     ALARM
  Pre-FEC BER min                              -     3.11e-05   1.00e-04   1.00e-05        N/A        N/A      WARN
  Temperature alarm exceeded                   -            0        N/A        N/A        N/A        N/A
  Temperature warn exceeded                    -            0        N/A        N/A        N/A        N/A
  Uncorrected BER avg                          -     0.00e+00   0.00e+00   0.00e+00        N/A        N/A
  Uncorrected BER high alarm exceeded          -            0        N/A        N/A        N/A        N/A
  Uncorrected BER high warn exceeded           -            0        N/A        N/A        N/A        N/A
  Uncorrected BER max                          -     0.00e+00   0.00e+00   0.00e+00        N/A        N/A
  Uncorrected BER min                          -     0.00e+00   0.00e+00   0.00e+00        N/A        N/A