Regulatory Model Numbers

This appendix lists the Regulatory Model Numbers (RMNs), where applicable, for the product models for the switches described in this document.

Table 1. Regulatory Model Numbers and Product Numbers
Regulatory Model Number (RMN) Product Number(s)
DCS-7060CX-32S DCS-7060CX-32S
DCS-7060CX2-32S DCS-7060CX2-32S
AN1622 DCS-7060SX2-48YC6
AN1709 DCS-7060PX4-32
AN1716 DCS-7060DX4-32
AN1790 DCS-7060DX4-32S

Maintenance and Field Replacement

The following topics are covered in this section:

Considerations

  • All fans and power supplies are hot swappable.
  • The switch can be running while a power supply is being installed or removed, but the power supply being replaced must not be connected to a power source.
  • All slots must be filled or covered with a blank for operation (even though power supply or fans may not be functional).
  • Before you begin, refer to the Arista Networks document Safety Information and Translated Safety Warnings available at: https://www.arista.com/en/support/product-documentation.

 

Note: Descriptions for the removal and replacement of power supplies and fans are for a representative power supply or fan. Locations of status indicator LEDs may differ. Refer to the front and rear panel illustrations of your device to locate the appropriate LED.

 

Power Supplies

The following steps are required when removing and replacing power supplies from a switch.

 

Note: Only a representative power supply module is shown in Figure 1. For the location of the power supply on your switch, refer to Rear Panel.

 

Removing a Power Supply

  1. Ground yourself with an ESD wrist strap.
  2. Power down the power supply to be removed by disconnecting the AC power cable.
  3. Push the power supply release lever and remove the power supply (Figure 1).
    Figure 1. Remove and Install Power Supply

     
    1 Release lever 2 Remove PSU

     

Installing a Power Supply

You must make space for installing the power supply by removing an existing one (Removing a Power Supply).
  1. Remove the replacement power supply from its packaging.
  2. Slide the new power supply into the empty slot.
  3. Slide the new power supply into the switch until the power supply is fully seated and the release lever snaps into place (Figure 1).
  4. Connect the power cord to the power supply.
  5. Verify the LED(s) on the power supply.
    Note: The Power Supply status LED should be a steady green for normal operation.
     
  6. Verify the new power supply operation by issuing the show environment power command.
    switch#show environment power
  7. The output of the command will list the power supplies in operation and should include the one you replaced.

Fan Modules

Note: Hot swap fans within 30 seconds to prevent the switch from overheating. Ensure that the module you are replacing matches those already installed in the switch.

 

Removing a Fan Module

The following steps are required when removing or replacing fans from a switch.

 

Note: Only a representative fan module is shown in Figure 2. For the location of the fan modules on your switch, refer to Rear Panel.

 

  1. Ground yourself with an ESD wrist strap.
  2. Push the fan module release lever and slide the fan module out of the switch (Figure 2).
    Figure 2. Removing Fan Module

     
    1 Release lever
     

Installing a Fan Module

You must make space for installing the fan module by removing an existing one (Removing a Fan Module).
  1. Remove the replacement fan from its packaging.
  2. Slide the new fan module into the switch until the module is fully seated and the release lever snaps into place (Figure 3).
    Figure 3. Inserting the Fan Module

  3. Verify that the fan module is working normally.
    Note: The fan module status LED should be a steady green for normal operation.

     

Rear Panel

All switches covered by this guide use one of the rear panels shown below. Depending on the installed power supply module, the appearance could be different from those shown.

 

Note: All devices are designed to fit into a 19” rack. The appearance may be different than those shown based on the PSU and the fan modules used.

 

Note: Handle or label color indicates airflow direction.

 

Figure 1. Rear Panel for Models with Management Ports in the Front

 
1 Power supply module 1 5 Fan module 4 9 Fan module 3 status LED
2 Fan module 1 6 Power supply module 2 10 Fan module 2 status LED
3 Fan module 2 7 PSU module 2 status LED 11 Fan module 1 status LED
4 Fan module 3 8 Fan module 4 status LED 12 PSU module 1 status LED

 

Figure 2. Rear Panel for Models with Management Ports in the Rear

 
1 Power supply module 1 5 Fan module 3 9 Earth grounding pad
2 Ethernet management port 6 Fan module 4 10 Console serial port
3 Fan module 1 7 Clock Input 11 USB port
4 Fan module 2 8 PSU 2    

 

Figure 3. DCS-7060PX4-32 and DCS-7060DX4-32 Rear Panel

 
1 Power supply module 1 6 Fan module 5 11 Fan module 3 status LED
2 Fan module 1 7 PSU 2 12 Fan module 2 status LED
3 Fan module 2 8 PSU 2 status LED 13 Fan module 1 status LED
4 Fan module 3 9 Fan module 5 status LED 14 PSU 2 status LED
5 Fan module 4 10 Fan module 5 status LED    

 

Front Panel

This appendix displays the front panel of all switches covered by this guide.

 

Note: All devices are designed to fit into a 19” rack. The appearance may be different than those shown based on the PSU and the fan modules used.

 

Figure 1. DCS-7060CX-32S

1 Ethernet management port 4 Power supply 1 status LED 7 Console serial port
2 System status LED 5 Power supply 2 status LED    
3 Fan status LED 6 USB port    

 

Figure 2. DCS-7060CX2-32S

1 Ethernet management port 4 Power supply 1 status LED 7 Console serial port
2 System status LED 5 Power supply 2 status LED    
3 Fan status LED 6 USB port    

 

Figure 3. DCS-7060SX2-48YC6

1 System status LED 3 Power supply 1 status LED
2 Fan status LED 4 Power supply 2 status LED

 

Figure 4. DCS-7060PX4-32

1 System status LED 3 Power supply 1 status LED
2 Fan status LED 4 Power supply 2 status LED

 

Figure 5. DCS-7060DX4-32, DCS-7060DX4-32S

1 System status LED 3 Power supply 1 status LED
2 Fan status LED 4 Power supply 2 status LED

 

Parts List

The following topics are covered in this section:

Each switch provides an accessory kit that contains parts that are required to install the switch. This appendix lists the installation parts contained in the switch accessory kit.

Rack Mount Parts

Four-Post Rack Mount Parts

Figure 1. Four-Post Rack Mount Parts

1 Rail-slide 3 Rack plugs
2 Rail-rod 4 Rail (assembled)

 

Two-Post Rack Mount Parts

Figure 2. Two-Post Rack Mount Parts

Cables

 
Quantity Description
2 Power cables: IEC-320/C13-C14, 13 A, 250 V
1 RJ-45 Patch Panel Cable
1 RJ-45 to DB9 Adapter Cable
Warning: All provided power cables are for use only with Arista products.

 



 

Status Indicators

The following topics are covered in this section:

Front Indicators

Switch Indicators

Front panel LEDs are located on the right side of the chassis and display system, fan, and power supply status. The front panel LEDs are labeled either as in Figure 1 or as in Figure 2. Check your device for the specific method utilized.

Figure 1. System Status Indicators

1 System status LED 3 Power supply 1 status LED
2 Fan status LED 4 Power supply 2 status LED

 

Figure 2. System Status Indicators

 
1 System status LED 3 Power supply 1 status LED
2 Fan status LED 4 Power supply 2 status LED

 

Table 1. Switch Indicators LED States (Front)
LED Name LED State Device Status
System Status LED Blinking Green System is powering up.
Green Normal operations. Due to power supply and fan redundancy, this LED will remain green if a single fan or power supply is missing or in a failed state.
Blue The locater function is active.
Amber Two or more fans (any combination of fan modules or PSU fans) are disconnected or malfunctioning. The switch will automatically execute a “graceful shutdown” shortly.
Fan Status LED Green All fan and power modules are operating normally.
Amber Single fan module is removed or malfunctioning. It is also amber when a PSU is completely removed or has a stuck fan rotor.
Red Two or more fans (any combination of fan modules or PSU fans) are disconnected or malfunctioning. The switch will automatically execute a “graceful shutdown” shortly.
PSU [1:2] Status LED Green PSU is functioning and fully operational. AC is present, Aux output is ON, and Main output is ON.
Off PSU has been removed or is not operating properly due to AC cord being unplugged, its fan rotor being stuck, or an internal fault.

 

Port Indicators

Port LEDs, located in the vicinity of their corresponding ports, provide link and operational status. Figure 3 displays the Port LED location on the DCS-7050QX-32S switch.

Figure 3. Port LEDs

 
1 Port 1 LEDs 3 Port 3 LEDs
2 Port 2 LEDs 4 Port 4 LEDs

 

Table 2 provides status conditions that correspond to port LED states. Port LED behavior for QSFP+ and SFP+ ports is consistent.

Table 2. Port LED States (Front)
LED State Status
Off Port link is down.
Green Port link is up.
Yellow Port is software disabled.
Flashing Yellow Port failed diagnostics.

 

Rear Status Indicators

Fan and power supply modules are accessed from the rear panel. Each fan and power supply module contains an LED that reports the module status.

Fan module status LEDs are on the fan modules, as displayed in Figure 4.

Figure 4. Fan Status LED

 
1 Fan module status LED

 

Table 3 provides status conditions that correspond to fan module status LED states.

Table 3. Fan Status LED States (Rear)
LED State Status
Off The fan module is not detected. If it is inserted, it may not be seated properly.
Green The fan is operating normally. This LED state is exclusive to its fan module, and independent of the states of its neighboring fans and power supplies.
Red The fan has failed.

 

The AC Power Supply Status LEDs are on the power supply modules, as displayed in Figure 5.

Figure 5. AC Power Supply Status LED

 
1 Power supply status LED

 

Table 4 provides status conditions that correspond to the AC power supply status LED states.

Table 4. AC Power Supply Status LED States (Rear)
Power Supply State PWR-500AC-F

PWR-500AC-R

Input power present Normal operation Green
Input power present Power Supply fault Yellow
No Input power Supply installed in chassis Off
Input power present Supply not installed in chassis Green

 

The DC Power Supply Status LEDs are on the power supply modules, as displayed in Figure 6.

Figure 6. DC Power Supply Status LED

 
1 Power supply status LED 3 Battery Return
2 -48V 4 Protective Earth

 

Table 5 provides status conditions that correspond to the DC power supply status LED states.

Table 5. DC Power Supply Status LED States (Rear)
Power Supply State PWR-500-DC-F

PWR-500-DC-R

Input power present Normal operation Green
Input power present Power Supply fault Blinking Yellow
No Input power Supply installed in chassis Off
Input power present Supply not installed in chassis Blinking Yellow

 

Note: You can narrow down the error condition by logging in to the switch to view the specific device state. Refer to the Arista User Manual’s Switch Environment Control chapter, under the topic Viewing Environment Status, for further information on the show environment commands.

 

Configuring the Switch

Arista switches ship from the factory in Zero Touch Provisioning (ZTP) mode. ZTP configures the switch without user intervention by downloading a startup configuration file or a boot script from a location specified by a DHCP server. To manually configure a switch, ZTP is bypassed. The initial configuration provides one username (admin) accessible only through the console port because it has no password.

When bypassing ZTP, initial switch access requires logging in as admin, with no password, through the console port. Then you can configure an admin password and other password protected usernames.

This manual configuration procedure cancels ZTP mode, logs into the switch, assigns a password to admin, assigns an IP address to the management port, and defines a default route to a network gateway.
  1. Provide power to the switch (Cabling the Switch).
  2. Connect the console port to a PC (Connecting Serial and Management Cables).

    As the switch boots without a startup-config file, it displays the following through the console:

    The device is in Zero Touch Provisioning mode and is attempting to
    download the startup-config from a remote system. The device will not
    be fully functional until either a valid startup-config is downloaded
    from a remote system or Zero Touch Provisioning is cancelled. To cancel
    Zero Touch Provisioning, login as admin and type 'zerotouch cancel'
    at the CLI.
    localhost login:
    
  3. Log into the switch by typing admin at the login prompt.
    localhost login:admin
  4. Cancel ZTP mode by typing zerotouch cancel.
    Important: This step initiates a switch reboot.
    localhost>zerotouch cancel
  5. After the switch boots, log into the switch again by typing admin at the login prompt.
    Arista EOS localhost 
    login:admin
    Last login: Fri Mar 15 13:17:13 on console
  6. Enter global configuration mode.
    localhost>enable
    localhost#config
  7. Assign a password to the admin username with the username secret command.
    localhost(config)#username admin secret pxq123
  8. Configure a default route to the network gateway.
    localhost(config)#ip route 0.0.0.0/0 192.0.2.1
  9. Assign an IP address (192.0.2.8/24 in this example) to an Ethernet management port.
    localhost(config)#interface management 1
    localhost(config-if-Ma1/1)#ip address 192.0.2.8/24
  10. Save the configuration by typing write memory or copy running-config startup-config.
    localhost#copy running-config startup-config
  11. When the management port IP address is configured, use this command to access the switch from a host, using the address configured in Step 9:
    ssh admin@192.0.2.8

Refer to the Arista Networks User Manual for complete switch configuration information.

Cabling the Switch

Grounding the Switch

After mounting the switch into the rack, connect the switch to the data center ground. Figure 1 displays the location of the grounding pads located on the bottom corners of the rear panel for the models that have no management ports on the rear panel. Figure 2 displays the location of the grounding pads on the rear panel for models that have management ports on the rear panel. There are threaded holes under the sticker on the right (next to PS2) that warns about “1 min”. Figure 3 displays the rear panel of the DCS-7060PX4-32 and DCS-7060DX4-32 devices.

 

Important: Grounding wires and grounding lugs (M4 x 0.7) are not supplied. Wire size should meet local and national installation requirements. Commercially available 6 AWG wire is recommended for installations in the U.S

À la terre et de mise à la terre fils cosses (M4 x 0.7) ne sont pas fournis. Calibre des fils doit satisfaire des exigences de l’installation locale et nationale. Disponible dans le commerce 6 fils AWG est recommandé pour les installations aux États-Unis.

 

Figure 1. Earth Grounding Pad Sockets for Models without Management Ports on the Rear Panel

1 Earth grounding pad

 

Figure 2. Earth Grounding Pad Sockets for Models with Management Ports on the Rear Panel

 
1 Earth grounding pad

 

Figure 3. DCS-7060PX4-32 and DCS-7060DX4-32 Rear Panel

 
1 Power supply module 1 6 Fan module 5 11 Fan module 3 status LED
2 Fan module 1 7 PSU 2 12 Fan module 2 status LED
3 Fan module 2 8 PSU 2 status LED 13 Fan module 1 status LED
4 Fan module 3 9 Fan module 5 status LED 14 PSU 2 status LED
5 Fan module 4 10 Fan module 5 status LED    

 

Note: Earth grounding pad is under label between fan module 5 and PSU 2.

 

Connecting Power Cables

Important: Installation of this equipment must comply with local and national electrical codes. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance.

Installation de cet équipement doit être conformes aux codes électriques locaux et nationaux. Si nécessaire, consulter les organismes de réglementation appropriés et des autorités de contrôle pour assurer la conformité.

 

The switch operates with two installed power supplies. At least one power supply must connect to a power source. Two circuits provide redundancy protection. Rear Panel displays the location of the power supplies on the rear panel of the switch.

 

Important: Read all installation instructions before connecting the system to the power source.

Lire toutes les instructions d’installation avant de brancher le système à la source d’alimentation.

 

  • Non-Redundant Configuration: Connect power to either of the two power supplies.
  • Redundant Power Supply Configuration: Connect power to both power supplies.
  • Power down the Switch: Remove all power cords and wires from the power supplies.

     

    Important: This equipment must be grounded. Never defeat the ground conductor.

    Cet équipement doit être mis à la terre. Ne jamais modifier le conducteur de terre.

     

    Important: This unit requires overcurrent protection.

    Cet appareil requiert une protection contre les surintensités.

     

AC Power Supplies

The following AC power supplies are supported.
  • PWR-500AC
  • PWR-1611-AC-RED

Figure 4 displays the two AC power supplies, including the power socket on the left side of the module. The AC power supply connects to a circuit that provides the required power, as specified by Table 4.

Figure 4. AC Power Supply

 
1 Power supply status LED

 

Note: Handle color indicates airflow direction.

 

The power supplies require power cables that comply with IEC-320 and have a C13 plug. The accessory kit provides two IEC-320 C13 to C14 power cables.

DC Power Supplies

The following DC power supplies are supported.

  • PWR-500-DC

    Figure 5. Supported DC Power Supplies

    1 Power supply status LED 3 Battery Return
    2 -48V 4 Protective Earth

     

    Important: A disconnect device must be provided as part of the installation.

    Un dispositif de sectionnement doit être fourni dans le cadre de l'installation.

     

    Important: Ensure power is removed from DC circuits before performing any installation actions. Locate the disconnect device, circuit breakers or fuses on DC power lines servicing the circuits. Turn off the power line circuits or remove the fuses.

    Pouvoir assurer qu'il est retiré de circuits DC avant d'effectuer des actions d'installation . Localiser les disjoncteurs ou des fusibles sur les lignes de courant continu desservant les circuits. Coupez les circuits de lignes d'alimentation ou retirer les fusibles.

     

    Important: Wire size must comply with local and national requirements and electrical codes. Use only copper wire.

    Le calibre du fil doit être conforme aux exigences locales et nationales et les codes électriques. Utiliser du fil de cuivre.

     

    Important: Apply ground connection to the switch first during installation and remove last when removing power.

    Appliquer connexion à la terre à l'interrupteur premier lors de l'installation et de supprimer la dernière alimentation lors du débranchement.

     

Connecting the PWR-500-DC Power Supply

The PWR-500W-DC power supply connects to a circuit that provides -48Vto -60V and 15A. Ensure the wires connecting the DC power supply to the power source meet the following:
  • DC Input Wire Size: AWG 14 (2.0 mm2) or larger as appropriate.
  • Safety Ground Wire Size: AWG 14 (2.0 mm2) or larger as appropriate.
  • Wire Terminal (Lug): ring or spade/fork, 14-16 AWG, #8 (4 mm) screw.
  • Over-current protection: 20 A.

     

    Important: Ensure power is removed from DC circuits before performing any installation actions. Locate circuit breakers or fuses on DC power lines servicing the circuits. Turn off the power line circuits or remove the fuses.

    Assurez-vous de pouvoir retirer des circuits en courant continu avant d’effectuer toute action d’installation.Localiser les disjoncteurs ou fusibles sur les lignes électriques DC entretien des circuits. Mettez hors tension le circuit ligne ou retirer les fusibles.

     

To connect a DC power supply to power source:
  1. Remove the terminal cover to expose the connectors on the terminal block on the face.
  2. Attach the appropriate lugs to the source DC wires.

    Use DC cables with either insulated crimp-on spade lugs or insulated crimp-on ring connectors.

     

    Important: Wire size must comply with local and national requirements and electrical codes. Use only copper wire.

    Calibre doit respecter les exigences locales et nationales et les codes de l’électricité. Utiliser seulement du fil de cuivre.

     

  3. Connect the DC-input wires to the terminal block in this order:
    1. Ground cable to the ground connector on the face of the power supply.
    2. Negative (–) source DC cable to the negative (–) connector on the terminal block.
    3. Positive (+) source DC cable to the positive (+) connector on the terminal block.
    4. Torque the screws to 1.0 N·m / 9 in·lb.

       

      Important: Apply the ground connection first during installation and remove last when removing power.

      Appliquer le motif connexion tout d’abord pendant l’installation et supprimer dernière lors du retrait de puissance.

       

    5. Replace the terminal cover.

Connecting Serial and Management Cables

The accessory kit includes the following cables:
  • RJ-45 to DB-9 serial adapter cable.
  • RJ-45 Ethernet cable.

Either the front panel or the rear panel has the console, management, and USB ports. Front Panel and Rear Panel display the front and rear panels of all switches covered by this guide.

Table 1 lists the pin connections of the RJ-45 to DB-9 adapter cable.

Table 1. RJ-45 to DB-9 Connections
RJ-45 DB-9   RJ-45 DB-9
RTS 1 8 CTS   GND 5 5 GND
DTR 2 6 DSR   RXD 6 3 TXD
TXD 3 2 RXD   DSR 7 4 DTR
GND 4 5 GND   CTS 8 7 RTS

 

Note: RJ-45 to DB-9 connections: For models with a console management port on the rear panel, RJ-45 pin 1 (RTS) is connected to RJ-45 pin 8 (CTS); RJ-45 pin 2 (DTR) and RJ-45 pin 7 (DSR) are not electrically connected to any signal.

 

Figure 6 displays the console, management, and USB ports in a representative configuration. Some earlier devices have ports where the USB port is located slightly differently.

Figure 6. Console, Management, and USB Ports

 
1 System status LED 3 Activity status LED 5 USB port
2 Ethernet management port 4 Serial console port 6 Link status LED

Connect the front or rear panel ports as follows:

  • Console (Serial) Port: Connect to a PC with the RJ-45 to DB-9 serial adapter cable. The switch uses the following default settings:
    • 9600 baud
    • No flow control
    • 1 stop bit
    • No parity bits
    • 8 data bits
  • Ethernet Management Port: Connect to 10/100/1000 management network with RJ-45 Ethernet cable.
  • USB Port: The USB port may be used for software or configuration updates.

     

    CAUTION: Excessive bending can damage interface cables, especially optical cables.

    Flexion excessive peut endommager les câbles d’interface, notamment des câbles optiques.

     

Rack Mounting the Switch

The following topics are covered in this section:

 

Important: The rack mounting procedure is identical for all switches covered by this guide. Illustrations in this chapter depict the mounting of a DCS-7050QX-32S switch.

Les procédure de montage du bâti est identique pour tous les commutateurs visés par ce guide. Illustrations dans ce chapitre montrent le montage d’un interrupteur de DCS-7050QX-32S.

 

After completing the instructions for your rack type, proceed to Cabling the Switch.

Two-Post Rack Mount

To mount the switch onto a two-post rack, assemble the mounting brackets to the chassis, then attach the brackets to the rack posts. Two-post accessory kits include the following two-post mounting parts:

2- Three-hole Mounting Bbrackets

Each chassis side has attachment pins that align with bracket holes. Pin orientation is symmetric and equidistant, supporting bracket placements where the flange is flush with the front switch panel, flush with the rear panel, or not flush with either panel. Each bracket hole includes a key-opening for placing the bracket flush with the chassis and then locking it into place.

 

Important: Attachment pins must engage all three upper bracket holes.

Goupilles de fixation doivent être bloquer tous les trois trous de la bride supérieure.

 

Figure 1 displays proper bracket mount configuration examples. Figure 2 displays improper bracket mount configuration examples.

 

Note: Center-mount is recommended for two-post racks.

Attaching Mounting Brackets to the Chassis

This procedure attaches mounting brackets to the switch chassis
  1. Align the mounting brackets with the attachment pins to obtain the desired mounting position.
  2. Place the bracket flush on the chassis with attachment pins protruding through key-openings.
    Figure 1. Bracket Mount Examples for Two-Post Rack Mount
    Figure 2. Improper Bracket Mount Eamples for Two-Post Rack Mount

  3. Slide the Bracket Toward the front Flange until the bracket clip locks with an audiable click.
    Figure 3. Attaching the Mounting Brackets to the Switch Chassis

    1 Step 1 4 Bracket clip (attached)
    2 Step 2 5 Bracket clip (aligned)
    3 Step 3    

     

    To remove the mounting bracket from the chassis, lift the front edge of the mounting bracket clip with a flathead screwdriver and slide the bracket away from the front flange (opposite from the installation direction).

Inserting the Switch into the Rack

This procedure attaches the switch to the rack.
  1. Lift the chassis into the rack. Position the flanges against the rack posts.
  2. Select mounting screws that fit your equipment rack.
  3. Attach the bracket flanges to the rack posts.
    Figure 4. Inserting the Switch into the Rack

After completing the two-post rack mount, proceed to Cabling the Switch.

Four-Post Rack Mount

The switch is mounted onto a four-post rack by assembling two rails onto the rear posts, sliding the switch onto the rails, then securing the switch to the front posts.

The installation kit provides the following four-post mounting parts:
  • 2 six-hole mounting brackets
  • 2 rail-rods
  • 2 rail-slides

The rail-rods and rail-slides assemble into two identical slide-rails.

Each chassis side has attachment pins that align with bracket holes. Pin orientation is symmetric and equidistant, supporting bracket placements where the flange is flush with the front switch panel, flush with the rear panel, or not flush with either panel. Each bracket hole includes a key-opening for placing the bracket flush with the chassis and then locking it into place.

 

Important: Attachment pins must engage at least five of the six bracket holes.

Goupilles de fixation doivent être lock au moins cinq des trous du six support.

 

Figure 5 displays proper bracket mount configuration examples. Figure 6 displays an improper bracket mount configuration example.

Figure 5. Bracket Mount Examples for Four-Post Rack Mount

Figure 6. Improper Bracket Mount Example for Four-Post Rack Mount

1 Bracket not attached by at least 5 pins

Attaching Mounting Brackets to the Chassis

Figure 7 displays the front bracket alignment for mounting the switch into a four-post rack.
Figure 7. Attaching the Mounting Brackets to the Switch Chassis

1 Attaching brackets for front mount
This procedure attaches mounting brackets to the switch chassis as depicted by Figure 7.
  1. Align the mounting brackets with the attachment pins to obtain the desired mounting position.
  2. Place the bracket flush on the chassis with attachment pins protruding through key-openings.
  3. Slide the bracket toward the front flange until the bracket clip locks with an audible click.

    To remove the mounting bracket from the chassis, lift the front edge of the mounting bracket clip with a flathead screwdriver and slide the bracket away from the front flange (opposite from the installation direction).

Assembling the Rails onto the Equipment Rack

Rail-rods and rail-slides assemble into two identical rails. Each rail connects a front post to a rear post. When the rails are installed, the switch slides on the rails into the rack. Each bracket includes a screw that attaches the switch to the rail.

Each end of an assembled rail contains two rack plugs (Attaching the Mounting Brackets to the Switch Chassis). The rails are installed into a rack by inserting the plugs into rack slots. When installing rails into posts with threaded or rounded holes, remove all plugs located on both sides of the assembled rails, then install the rails with bolts that fit the rack.

Figure 8. Attaching the Mounting Brackets to the Switch Chassis

1 Step 1 4 Bracket clip (attached)
2 Step 2 5 Bracket clip (aligned)
3 Step 3    

 

This procedure attaches the rails to a four post rack:
  1. Slide a rail-rod into a rail-slide (Figure 9) until the rail clip makes an audible click.

    The rail clip prevents the extension of the rail beyond the maximum supported distance between the front and rear rack posts.

    Figure 9. Assembling the Rails

    1 Rail-slide 3 Rack plugs
    2 Rail-rod 4 Rail (assembled)
           

     

  2. Attach rail to the right rear rack post by inserting rod-end rack plugs into post slots (Attaching the Rails - Inset A). The slide assembly must be inside the right posts, relative to the left rack posts.

    If the rack plugs were previously removed, use bolts to attach the rail to the rack.

  3. Attach the slide end of the rail to the front post by extending the rail end past the post, then contracting the rail while guiding the rack plugs into the post (Attaching the Rails - Inset B).
  4. Repeat Step 1 through Step 3 for the left posts. Ensure the rails are on the same horizontal level.
    Figure 10. Attaching the Rails

    1 Inset A 2 Inset B

     

Attaching the Switch to the Rack

After the rails are installed, the switch slides on the rails into the rack. Each bracket includes a thumb screw that attaches the switch to the rail.
  1. Lift the switch into the rack and insert the mounting brackets into the slide rails(Figure 11).
    Figure 11. Inserting the Switch onto the Rails

  2. Slide the switch on the rails, toward the rear posts, until the mounting bracket flanges are flush with the rail flanges attached to the rack posts.
  3. Attach the bracket flanges to the rack post using the quick-release thumb screws supplied with the brackets (Figure 12).
    Figure 12. Attaching the Switch to the Rack Posts

After completing the four-post rack mount, proceed to Cabling the Switch.