Security Advisory 0032
Date: March 1st, 2018
Version: 1.0
Revision | Date | Changes |
---|---|---|
1.0 | March 1st, 2018 | Initial Release |
Affected Platforms: All EOS platforms
Affected Software Version: This issue was introduced in EOS-4.19.0F release.
The CVE-ID tracking this issue is CVE-2018-5255
CVSS v3: 5.8 CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:L
Impact:
This advisory is to document a security vulnerability that affects Arista products. The switch’s Mlag agent may restart unexpectedly when processing malformed UDP packets on a specific UDP port destined to the switch’s ip address. Such malformed UDP packets with specific port numbers are not expected to be received in typical production environments and have to be crafted and sent with the malformed values by a malicious user.
BUG 234146 tracks the potential crash that can be caused by this vulnerability.
The backtrace of the crash file will have the following information if the Mlag agent restarted because of this vulnerability.
.... File "/usr/lib/python2.7/site-packages/MlagShared.py", line 118, in validateHeartbeatPkt struct.unpack( UDPHEARTBEAT_HDR_FORMAT, hdr )......
Mitigation:
BUG 234146 tracks this vulnerability. A fix for this issue is available from SW versions 4.19.4M , 4.20.2F onwards.
Resolution: It is recommended to upgrade EOS to versions with the fix or install the patch provided on affected versions of EOS
Patch file download URL:
CVE-2018-5255-4-19-hotfix.swix for SW versions 4.19.0F, 4.19.1F, 4.19.2F, 4.19.2.1F, 4.19.2.2F, 4.19.3F
CVE-2018-5255-4-20-hotfix.swix for SW versions 4.20.1F
Sha256 sum is:
[admin@switch flash]$ sha256sum CVE-2018-5255-4-20-hotfix.swix 0d74ca3d1ea054d388aece073968c8d2c3d153df861230f2a4bb9871bcb49b58 CVE-2018-5255-4-20-hotfix.swix
[admin@switch flash]$ sha256sum CVE-2018-5255-4-19-hotfix.swix 6ed06ff7b8cc33bfd6b2e50725ff215b0abe1b4d44601d824e31efa0a23cae93 CVE-2018-5255-4-19-hotfix.swix
Note:
- This hotfix can be installed on the affected versions of EOS.
- Installing the patch will restart the MLAG agent that could lead to a momentary disruption in traffic forwarding.
- A reload of the switch is not required for the patch to take effect
Instructions to install the patch:
- Download the patch file and copy the file to the extension partition of the switch using one of the supported file transfer protocols:
switch#copy scp://10.10.0.1/CVE-2018-5255-4-20-hotfix.swix extension: switch#verify /sha256 extension:CVE-2018-5255-4-20-hotfix.swix
- Verify that the checksum value returned by the above command matches the provided SHA256 checksum for the file
- Install the patch using the extension command. The patch takes effect immediately at the time of installation.
switch#extension CVE-2018-5255-4-20-hotfix.swix
- Verify that the patch is installed using the following commands:
switch#show extensions Name Version/Release Status Extension ----------------------------------- -------------------- ----------- --------- CVE-2018-5255-4-20-hotfix.swix 1.0.2/7318675.\ A, I 1 vmahadberlinA1\ patch234146.4
- Make the patch persistent across reloads. This ensures that the patch is installed as part of the boot-sequence. The patch will not install on EOS versions with the security fix.
switch#copy installed-extensions boot-extensions switch#show boot-extensions CVE-2018-5255-4-20-hotfix.swix
- For dual supervisor systems run the above copy command on both active and standby supervisors:
switch(s1)#copy installed-extensions boot-extensions switch(s2-standby)#copy installed-extensions to boot-extensions
References:
CVE-2018-5255
For More Information:
If you require further assistance, or if you have any further questions regarding this security notice, please contact the Arista Networks Technical Assistance Center (TAC) by one of the following methods:
Open a Service Request:
By email: 이 이메일 주소가 스팸봇으로부터 보호됩니다. 확인하려면 자바스크립트 활성화가 필요합니다.
By telephone: 408-547-5502