Overview
Scope
This guide is intended for properly trained service personnel and technicians who need to install the following Arista Networks Data Center Switches:
- DCS-7280CR2A-30
- DCS-7280CR2K-30
- DCS-7280CR2M-30
Only qualified personnel should install, service, or replace this equipment.
Seul le personnel qualifié doit installer, service, ou remplacer cet équipement.
Receiving and Inspecting the Equipment
Upon receiving the switch, inspect the shipping boxes and record any external damage. Retain packing materials if you suspect that part of the shipment is damaged; the carrier may need to inspect them.
If the boxes were not damaged in transit, unpack them carefully. Ensure that you do not discard any accessories that may be packaged in the same box as the main unit.
Inspect the packing list and confirm that you received all listed items. Compare the packing list with your purchase order. Parts List provides a list of components included with the switch.
Installation Process
Safety Information
Refer to the Arista Networks document Safety Information and Translated Safety Warnings available at: https://www.arista.com/en/support/product-documentation.
Obtaining Technical Assistance
Any customer, partner, reseller, or distributor holding a valid Arista Service Contract can obtain technical support in any of the following ways:
- Email: This email address is being protected from spambots. You need JavaScript enabled to view it.. This is the easiest way to create a new service request.
Include a detailed description of the problem and the output of “show tech-support”.
- Web: http://www.arista.com/en/support.
A support case may be created through the support portal on our website. You may also download the most current software and documentation, as well as view FAQs, Knowledge Base articles, Security Advisories, and Field Notices.
- Phone: +1 866-476-0000 or +1 408-547-5502.
No user serviceable parts inside. Refer all servicing to qualified service personnel.
Aucune pièce réparable par l'utilisateur à l'intérieur. Confiez toute réparation à un technicien qualifié.
Specifications
Switch | Size (W x H x D) | Weight |
---|---|---|
DCS-7280CR2A-30 | 48.3 x 4.4 x 67.1 cm (19 x 1.75 x 26.4 inches) | 15.5 kg (34.2 lbs.) |
DCS-7280CR2K-30 | 48.3 x 4.4 x 67.1 cm (19 x 1.75 x 26.4 inches) | 15.5 kg (34.2 lbs.) |
DCS-7280CR2M-30 | 48.3 x 4.4 x 67.1 cm (19 x 1.75 x 26.4 inches) | 15.5 kg (34.2 lbs.) |
Switch | Operating Temperature | Storage Temperature | Operating Altitude | Relative Humidity |
---|---|---|---|---|
All | 0° to 40°C (32° to 104°F) | -25° to 70°C (-13° to 158°F) | 0 to 3,000 meters (0 to 10,000 feet) | 5 to 90% (non-condensing) |
Power Source | PSU Models | Ratings 1 |
---|---|---|
Power Input (AC Power) | PWR-1600AC | 100 to 240 VAC, 12.9 to 9.5 A, 50/60 Hz |
Power Input (DC Power) | PWR-1611-DC | -48 to -60 VDC, 39 A |
1. AC PSUs could be rated for lower maximum power at lower line voltage.
2. The AC PSU fans will not be operational if the power cord is not connected.
A power supply unit could be used in multiple Arista switches.
For power consumed by a specific model or configuration, refer to the relevant power draw specification or contact your Arista representative.
Switch | Power Draw (Typical / Maximum) | Supported Power Supply |
---|---|---|
DCS-7280CR2A-30 | 563 W / 628 W | PWR-1600AC, PWR-1611-DC |
DCS-7280CR2K-30 | 563 W / 628 W | PWR-1600AC, PWR-1611-DC |
DCS-7280CR2M-30 | 1300 W / 1400 W | PWR-1600AC, PWR-1611-DC |