Preparation

Site Selection

The following criteria should be considered when selecting a site to install the switch.

  • Temperature and Ventilation: For proper ventilation, install the switch where there is ample airflow to the front and back of the switch. The ambient temperature should not go below 0° or exceed 40°C.
    Important: To prevent the switch from overheating, do not operate it in an area where the ambient temperature exceeds 40°C (104°F).

    Pour empêcher l’interrupteur de surchauffe, ne pas utiliser il dans une zone où la température ambiante est supérieure à 40°C (104°F).

  • Airflow Orientation: The fans and PSUs determine the airflow direction through the switch. The color of the visible handles or labels indicate the airflow direction.
    Note: The figures shown use representative Arista switches to illustrate airflow directions. Refer to Rear Panel to determine the airflow for your switch.
    • Blue Handle: Air Inlet module. The following figure shows the airflow through the switch with air inlet modules:
      Figure 1. Air Inlet Module

       

    • Red Handle: Air Exit module. The following figure shows the airflow through the switch with air exit modules:
      Figure 2. Air Exit Module
    Orient the switch such that the airflow through the switch is from the cooler to the hotter aisle. If the airflow direction is not compatible with the installation site, reorient the fan modules to circulate air in the opposite direction.
Figure 3 displays fan and power supply module locations on the rear panel. Their red handles indicate that they are air exit modules. Verify that each module has the same airflow direction. Base the switch orientation on the airflow direction of the modules to assure the air inlet is always oriented toward the cool aisle:
  • Air Exit modules: orient the rear panel toward the hot aisle.
  • Air Inlet modules: orient the rear panel toward the cool aisle.

If the airflow direction is not compatible with the installation site, contact your sales representative to obtain modules that circulate air in the opposite direction.

  • Rack Space: Install the switch in a 19" rack or cabinet. The switch height is 1 RU. The accessory kit provides mounting brackets for two-post and four-post racks.

When mounting the switch in a partially filled rack, load the rack from bottom to top, with the heaviest equipment at the bottom. Load the switch at the bottom if it is the only item in the rack.

  • Power Requirements: Power requirements vary by switch and power supply model. Table 3 and Table 4 provide information regarding your specific system.

    Two circuits provide redundancy protection. Cabling the Switch describes power cable requirements.

    Figure 3. Airflow Direction Labels
    1 Power supply module 1 label 5 Fan module 4 9 Fan module 3 status LED
    2 Fan module 1 6 Power supply module 2 label 10 Fan module 2 status LED
    3 Fan module 2 7 Fan module handl 11 Fan module 1 status LED
    4 Fan module 3 8 Fan module 4 status LED 12 PSU 1 status LED
    Note: Handle or label color indicates airflow direction.
    Important: The power input plug-socket combination must be accessible at all times; it provides the primary method of disconnecting power from the system.

     

    La combinaison de la puissance-prise d’entrée doit être accessible en tout temps ; Il fournit le principal moyen de coupure d’alimentation du système.

     

  • Other Requirements: Select a site where liquids or objects cannot fall onto the equipment and foreign objects are not drawn into the ventilation holes. Verify these guidelines are met:
    • Clearance areas to the front and rear panels allow for unrestricted cabling.
    • All front and rear panel indicators can be easily read.
    • Power cords can reach from the power outlet to the connector on the rear panel.
      Important: All power connections must be removed to de-energize the unit.

      Toutes les connexions d’alimentation doivent être enlevées pour hors tension l’appareil.

Tools and Parts Required for Installation

Each switch provides an accessory kit that contains parts that are required to install the switch.

In addition to the accessory kit, the following tools and equipment are required to install the switch:

Two-Post Rack

  • Screws or rack mounting nuts and bolts.
  • Screwdriver

Four-Post Rack (Tool-less)

No additional equipment required.

Four-Post Rack (Conventional)

  • Screws or rack mounting nuts and bolts.
  • Screwdriver

Accessory kit does not include screws for attaching the switch to the equipment rack. When installing the switch into an equipment rack with unthreaded post holes, nuts are also required to secure the switch to the rack posts.

Electrostatic Discharge (ESD) Precautions

Observe these guidelines to avoid ESD damage when installing or servicing the switch.

  • Assemble or disassemble equipment only in a static-free work area.
  • Use a conductive work surface (such as an anti-static mat) to dissipate static charge.
  • Wear a conductive wrist strap to dissipate static charge accumulation.
  • Minimize handling of assemblies and components.
  • Keep replacement parts in their original static-free packaging.
  • Remove all plastic, foam, vinyl, paper, and other static-generating materials from the work area.
  • Use tools that do not create ESD.

Overview

This guide is intended for properly trained service personnel and technicians who need to install selectedArista Networks Data Center Switches.

Scope

This guide covers the following devices:

DCS-7280SE-64 DCS-7280SE-68 DCS-7280SE-72 DCS-7280QR-C36
DCS-7280TR-48C6 DCS-7280SR2A-48YC6 DCS-7280TRA-48C6 DCS-7280QRA-C36S
DCS-7280SRAM-48C6 DCS-7280SR-48C6 DCS-7280SR2-48YC6 DCS-7280SRA-48C6
DCS-7280SR2K-48C6 DCS-7280SRM-40CX2 DCS-7280CR3-32D4 DCS-7280CR3-32P4
DCS-7280DR3-24 DCS-7280PR3-24 DCS-7280SR3-48YC8 DCS-7280SR3K-48YC8
DCS-7280CR3K-32D4 DCS-7280CR3K-32P4 DCS-7280DR3K-24 DCS-7280PR3K-24
DCS-7280CR3-36S DCS-7280CR3K-36S    
Important: Only qualified personnel should install, service, or replace this equipment.

 

Seul le personnel qualifié doit installer, service, ou remplacer cet équipement.

Receiving and Inspecting the Equipment

Upon receiving the switch, inspect the shipping boxes and record any external damage. Retain packing materials if you suspect that part of the shipment is damaged; the carrier may need to inspect them.

If the boxes were not damaged in transit, unpack them carefully. Ensure that you do not discard any accessories that may be packaged in the same box as the main unit.

Inspect the packing list and confirm that you received all listed items. Compare the packing list with your purchase order. Parts List provides a list of components included with the switch.

Installation Process

This section discusses the task required to install and use the switch.

  1. Select and prepare the installation site (Site Selection).
  2. Assemble the installation tools (Tools and Parts Required for Installation).
  3. Attach the mounting brackets and install the switch in an equipment rack (Rack Mounting the Switch).
  4. Connect the switch to the power source and network devices (Cabling the Switch).
  5. Configure the switch (Configuring the Switch).
    Important: Class 1 Laser Product: This product has provisions to install Class 1 laser transceivers which provide optical coupling to the communication network. Once a Class 1 laser product is installed, the equipment is a Class 1 Laser Product (Appareil à Laser de Classe 1). The customer is responsible for selecting and installing the Class 1 laser transceiver and for insuring that the Class 1 AEL (Allowable Emission Limit) per EN/IEC 60825, CSA E60825-1, and Code of Federal Regulations 21 CFR 1040 is not exceeded after the laser transceiver have been installed. Do not install laser products whose class rating is greater than 1. Refer to all safety instructions that accompanied the transceiver prior to installation. Only Class 1 laser devices, certified for use in the country of installation by the cognizant agency are to be utilized in this product. Ultimate disposal of this product should be in accordance with all applicable laws and regulations.

     

    Produit Laser de classe 1: Ce produit a des dispositions pour installer des émetteurs-récepteurs de laser de classe 1 qui offre de couplage au réseau de communication optique.Une fois un produit laser de classe 1 est installé, l'équipement est un produit Laser de classe 1 (Appareil à Laser de Classe 1).Le client est responsable pour sélectionner et installer l'émetteur/récepteur de laser de classe 1 et pour assurer que la classe 1 AEL (limite d'émission admissible) par EN/IEC 6-825, CSA E60825-1, et Code des règlements fédéraux 21 CFR 1040 ne soit pas dépassée après avoir installé l'émetteur/récepteur de laser. Ne pas installer des appareils à laser dont la cote de classe est supérieure à 1.Voir toutes les consignes de sécurité qui ont accompagné l'émetteur-récepteur avant l'installation. Seuls appareils laser de classe 1 certifiés pour une utilisation dans le pays d’installation par l’organisme compétent doivent être utilisées dans ce produit.

    Important: Ultimate disposal of this product should be handled in accordance with all national laws and regulations.

     

    Aucune pièce réparable par l'utilisateur à l'intérieur. Confiez toute réparation à un technicien qualifié.

Obtaining Technical Assistance

Any customer, partner, reseller or distributor holding a valid Arista Service Contract can obtain technical support in any of the following ways.

Specifications

List of specifications of Arista data center modular switches and components covered by this guide.

Table 1. Switch Specifications (Dimensions and Weights)
Switch Size (W x H x D) Weight
DCS-7280SE-64 48.3 x 4.4 x 52.3 cm (19 x 1.75 x 20.6 inches) 10.0 kg (22.0 lbs.)
DCS-7280SE-68 48.3 x 4.4 x 52.3 cm (19 x 1.75 x 20.6 inches) 10.1 kg (22.3 lbs.)
DCS-7280SE-72 48.3 x 4.4 x 52.3 cm (19 x 1.75 x 20.6 inches) 10.2 kg (22.5 lbs.)
DCS-7280QR-C36 48.3 x 4.4 x 52.3 cm (19 x 1.75 x 20.6 inches) 9.7 kg (21.4 lbs.)
DCS-7280TR-48C6 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches) 10.1 kg (22.3 lbs.)
DCS-7280SR2A-48YC6 48.3 x 4.4 x 52.3 cm (19 x 1.75 x 20.6 inches) 10.4 kg (22.9 lbs.)
DCS-7280TRA-48C6 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches) 10.1 kg (22.3 lbs.)
DCS-7280QRA-C36S 48.3 x 4.4 x 52.3 cm (19 x 1.75 x 20.6 inches) 10.7 kg (23.6 lbs.)
DCS-7280SRAM-48C6 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches) 9.0 kg (20.0 lbs.)
DCS-7280SR-48C6 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches) 10.0 kg (22.0 lbs.)
DCS-7280SR2-48YC6 48.3 x 4.4 x 52.3 cm (19 x 1.75 x 20.6 inches) 10.4 kg (22.9 lbs.)
DCS-7280SRA-48C6 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches) 8.6 kg (19.0 lbs.)
DCS-7280SR2K-48C6 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches) 9.0 kg (20.0 lbs.)
DCS-7280SRM-40CX2 44.0 x 4.4 x 40.2 cm (17.3 x 1.75 x 15.8 inches) 8.7 kg (19.1 lbs.)
DCS-7280CR3-32D4 48.3 x 4.4 x 55.8 cm (19 x 1.75 x 22.0 inches) 12.3 kg (27.0 lbs.)
DCS-7280CR3-32P4 48.3 x 4.4 x 55.8 cm (19 x 1.75 x 22.0 inches) 12.3 kg (27.0 lbs.)
DCS-7280DR3-24 48.3 x 4.4 x 57.4 cm (19 x 1.75 x 22.6 inches) 13.1 kg (29.0 lbs.)
DCS-7280PR3-24 48.3 x 4.4 x 58.2 cm (19 x 1.75 x 23.6 inches) 12.7 kg (28.0 lbs.)
DCS-7280SR3-48YC8 48.3 x 4.4 x 46.7 cm (19 x 1.75 x 18.4 inches) 9.2 kg (20.2 lbs.)
DCS-7280SR3K-48YC8 48.3 x 4.4 x 46.7 cm (19 x 1.75 x 18.4 inches) 9.2 kg (20.2 lbs.)
DCS-7280CR3K-32D4 48.3 x 4.4 x 55.8 cm (19 x 1.75 x 22.0 inches) 12.3 kg (27.0 lbs.)
DCS-7280CR3K-32P4 48.3 x 4.4 x 55.8 cm (19 x 1.75 x 22.0 inches) 12.3 kg (27.0 lbs.)
DCS-7280DR3K-24 48.3 x 4.4 x 57.4 cm (19 x 1.75 x 22.6 inches) 13.1 kg (29.0 lbs.)
DCS-7280PR3K-24 48.3 x 4.4 x 58.2 cm (19 x 1.75 x 23.6 inches) 12.7 kg (28.0 lbs.)
DCS-7280CR3-36S 48.3 x 4.4 x 47.2 cm (19 x 1.75 x 18.6 inches) 10.5 kg (23.0 lbs.)
DCS-7280CR3K-36S 48.3 x 4.4 x 47.2 cm (19 x 1.75 x 18.6 inches) 10.5 kg (23.0 lbs.)

 

 

Table 2. Switch Specifications (Operational and Storage)
Switch Operating Temperature Storage Temperature Operating Altitude Relative Humidity
All 0° to 40°C (32° to 104°F) -25° to 70°C (-13° to 158°F) 0 to 3,000 meters (0 to 10,000 feet) 5 to 90% (non-condensing)

 

 

Table 3. Switch Specifications (Power Input)
Power Source PSU Models Ratings
Power Input (AC Power) PWR-500AC 100 - 240 VAC, 6.5 to 3.0 A, 50/60 Hz
PWR-511-AC 100 - 240 VAC< 7.1 A, 50/60 Hz
PWR-745AC 100 - 240 VAC 10.0 to 5.0 A 50/60 Hz
PWR-747AC 100 - 240 VAC 10.0 to 5.0 A 50/60 Hz
PWR-1011-AC 100 - 120 / 200 - 240 VAC 12 / 6 A 50/60 Hz
PWR-1511-AC 200 - 240 VAC 9.6 A 50/60 Hz
Power Input (DC Power) PWR-500-DC -48 to -60 VDC, 15 A-48 to -60 VDC
PWR-511-DC
PWR-1011-DC 13 A -40 to -60 VDC, 30 A -48 to -60 VDC
PWR-1511-DC
PWR-1900-DC 39.5 A -48 to -60 VDC 52 A

 

Note: All PSU models are not supported by all switches. Some switches described in this guide could use power supplies that may no longer be available. Contact your local Arista representative for more information.

 

Table 4. Switch Specifications (Power Draw)
Switch Power Draw (Typical / Maximum) Supported Power Supply
DCS-7280SE-64 263 W / 381 W PWR-500AC, PWR-500-DC
DCS-7280SE-68 313 W / 405 W PWR-500AC, PWR-500-DC
DCS-7280SE-72 262 W / 399 W PWR-500AC, PWR-500-DC
DCS-7280QR-C36 324 W / 499 W PWR-745AC, PWR-1900-DC
DCS-7280TR-48C6 290 W / 405 W PWR-500AC, PWR-500-DC
DCS-7280SR2A-48YC6 450 W / 685 W PWR-747AC, PWR-1900-DC
DCS-7280TRA-48C6 290 W / 405 W PWR-500AC, PWR-500-DC
DCS-7280QRA-C36S 419 W / 570 W PWR-747AC, PWR-1900-DC
DCS-7280SRAM-48C6 355 W / 400 W PWR-500AC, PWR-500-DC
DCS-7280SR-48C6 263 W / 381 W PWR-500AC, PWR-500-DC
DCS-7280SR2-48YC6 425 W / 647 W PWR-747AC, PWR-1900-DC
DCS-7280SRA-48C6 314 W / 410 W PWR-500AC, PWR-500-DC
DCS-7280SR2K-48C6 215 W / 370 W PWR-747AC, PWR-1900-DC
DCS-7280SRM-40CX2 183 W / 283 W PWR-500AC, PWR-500-DC
DCS-7280CR3-32D4 535 W / 851 W PWR-1011-AC, PWR-1011-DC
DCS-7280CR3-32P4 535 W / 851 W PWR-1011-AC, PWR-1011-DC
DCS-7280DR3-24 560 W / 1110 W PWR-1511-AC, PWR-1511-DC
DCS-7280PR3-24 650 W / 1100 W PWR-1511-AC, PWR-1511-DC
DCS-7280SR3-48YC8 155 W / 325 W PWR-511-AC, PWR-511-DC
DCS-7280SR3K-48YC8 155 W / 325 W PWR-511-AC, PWR-511-DC
DCS-7280CR3K-32D4 535 W / 851 W PWR-1011-AC, PWR-1011-DC
DCS-7280CR3K-32P4 535 W / 851 W PWR-1011-AC, PWR-1011-DC
DCS-7280DR3K-24 560 W / 1110 W PWR-1511-AC, PWR-1511-DC
DCS-7280PR3K-24 650 W / 1100 W PWR-1511-AC, PWR-1511-DC
DCS-7280CR3-36S 254 W / 423 W PWR-1011-AC, PWR-1011-DC
DCS-7280CR3K-36S 254 W / 423 W PWR-1011-AC, PWR-1011-DC
Quick Start Guide
7280 Series 1 RU (Gen 3)
Data Center Switches
Arista Networks

www.arista.com

PDOC-00144-05

Headquarters
5453 Great America Parkway
Santa Clara, CA 95054, USA
+1-408 547-5500
www.arista.com
Support
+1-408 547-5502
+1-866 476-0000
This email address is being protected from spambots. You need JavaScript enabled to view it.
Sales
+1-408 547-5501
+1-866 497-0000
This email address is being protected from spambots. You need JavaScript enabled to view it.
© Copyright 2022 Arista Networks, Inc. The information contained herein is subject to change without notice. Arista Networks and the Arista logo are trademarks of Arista Networks, Inc., in the United States and other countries. Other product or service names may be trademarks or service marks of others.