Status Indicators

Supervisor Module

While the front panel of each switch can house two supervisors, switch operations require only one. Supervisors display switch component status and contain Ethernet management and console ports.

Supervisor Indicators: 7500E-SUP/7500-SUP2

The supervisor provides:
  • One serial console port.
  • Two Ethernet management ports.
  • Two USB ports.
  • One clock input port.

     

Supervisor activity is reported by LEDs in the upper left corner. Four LEDs on the left of the input ports report the status of other switch components.

 

Figure 1. Supervisor 7500E-SUP
1 Status LED 2 USB ports 3 Ethernet management ports
4 Serial console port 5 Fan module status LED 6 Fabric module status LED
7 linecard status LED 8 Power supply status LED 9 Active LED

 

 

Figure 2. Supervisor 7500-SUP 2
1 Status LED 2 USB ports 3 Ethernet management ports
4 Serial console port 5 Clock input port (optional) 6 Fan module status LED
7 Fabric module status LED 8 linecard status LED 9 Power supply status LED
10 Active LED        

 

 

Figure 3. Supervisor 7500E-SUP
1 Status LED 2 USB ports 3 Ethernet management ports
4 Serial console port 5 Clock input port (optional) 6 Fan module status LED
7 Fabric module status LED 8 linecard status LED 9 Power supply status LED
10 Active LED        

 

Supervisor Activity Status LEDs

The Status and Active LEDs are located on the left side of the Supervisor Module. Table 1 interprets the states of these two LEDs.

 

Table 1. Supervisor Activity LED States
LED Name LED State Supervisor State
Status Off No power, failed, or improperly inserted.
Green Operating normally.
Red Supervisor failed.
Active Off Not active.
Green Active and controlling the switch.

 

Component Activity Status LEDs

LEDs located below the vents and left of the input ports display summary indicators for power supplies, fabric modules, fans, and linecards. Table 2 interprets the states of these indicators. When error conditions are indicated, refer to LEDs on the specified modules to determine the condition’s source.

 

Table 2. Component Activity LED States
LED Name LED State Module State
Power Supply, linecard Fabric Module Fans Off No modules are present or powered.
Green All powered modules are operating normally.
Red One or more components failed.

 

linecard Module Indicators

Each linecard module provides one status LED plus LEDs for each port on the card. The figures in linecards indicate the location of the LEDs on each linecard.

 

Figure 4. linecard Status LED
1 Status LED 2 QSFP port 4 LEDs 3 QSFP port 3 LEDs
4 QSFP port 2 LEDs 5 QSFP port 1 LEDs 6 10G / 40G /100G QSFP port LEDs

 

 

Table 3 interprets the states of the status LED.

 

Table 3. linecard Status LED States
LED State Status
Off linecard not inserted.
Green linecard operating normally.
Yellow linecard administratively shut down.
Red linecard has failed.

 

The linecard provides LEDs for each port module socket:

  • Each LED corresponds to a module.
  • A set of four LEDs correspond to each module. When the module is programmed as a 40G port, the first LED in the set reports status. When the module is programmed as four 10G or 100G ports, each port is assigned to an LED within the set.

     

Table 4 interprets the port LED states.

 

Table 4. linecard Port LED States
LED State Status
Off Port link is down.
Green Port link is up.
Yellow Port is disabled in software.

 

Fabric Status Indicators

Fabric Status LEDs are on fan-fabric modules. The Rear Panel displays the position of these LEDs on the rear of each switch. Figure 5 display fan status and fabric status LEDs on the switch.

 

Note: Gen 1 Fabric modules are not supported.

 

Figure 5. 7504N (left) and 7508N Fan and Fabric Status LEDs
1 Fan status LED 3 Fabric status LED
2 Fabric status LED 4 Fan status LED

 

 

Figure 6. 7512N (left) and 7516N Fan and Fabric Status LEDs
1 Fabric status LED 2 Fan status LED

 

 

Table 5 interpret the fan and fabric status LED states.

 

Table 5. Fan and Fabric Status LEDs on the Rear Panel
LED State Status
Off Module inserted, but the status is unknown.
Green Module operates normally
Red Module failed

 

Power Supply Status Indicators

  • PWR-3KT-AC RED
  • PWR-2700-DC-R
  • PWR-3K-DC-RED

     

The power supply LEDs are on the power supply modules. The positions of the LEDs are on the rear of each switch. Figure 7 display all the power supply modules supported on the 7500n.

 

Figure 7. 7500n Power Supplies

 

 

Note: The LEDs for the power supplies with three LED status indicators from top to bottom are:
  • DC Good
  • Fault, and
  • Vin Good

 

Table 6 interprets the power supply set up for LED status indicators.

 

Table 6. Power Supply Status LED States
Power Supply State LED Name PWR-3KT-AC-Red PWR-2700-DC-R PWR-3K-DC-Red
Input power present Normal Operation DC Good Fault Vin Good Green Off Green Green Off Green Green
Input power present Main output off DC Good Fault Vin Good Off Off Green Off Off Green Blinking Green
Input power present Power Supply Fault DC Good Fault Vin Good Off Blinking Amber Green Off Blinking Amber Green Blinking Amber, 1 sec on, 1 sec off
No Input Power Supply installed in chassis DC Good Fault Vin Good Off Off Off Off Off Off Off
Input power present Supply not seated in chassis DC Good Fault Vin Good Off Off Blinking Green Off Off Off Blinking Amber, 0.5 sec on/off