Specifications
The following Appliance Specifications table lists the specifications of the Arista DCA-200-CV and DCA-250-CVCloudVision Appliance.
System | Dimensions |
Xa | 482.0 mm (18.97 inches) |
Xb | 434.0 mm (17.08 inches) |
Y | 42.8 mm (3.41 inches) |
Za | 35.84 mm (1.41 inches) (with bezel)
22 mm (0.87 inches) (without bezel) |
Zb | x4 and x10 = 657.25 mm (25.87 inches)
x8 = 606.47 (23.87 inches) |
Zc | x4 and x10 = 692.62 (27.26 inches)
x8 = 641.85 mm (25.26 inches) |
Weight | Maximum weight (with all drives/SSDs) |
4 x 3.5-inch drive system | 17.64 Kg (38.90 lb) |
8 x 2.5-inch drive system | 16.04 Kg (35.36 lb) |
10 x 2.5-inch drive system | 16.81 Kg (37.07 lb) |
Power Draw | Specifications |
Power Draw (Typical) 550 W AC | Platinum 50/60 Hz 100 240 V AC, auto-arranging |
Power Draw (Typical) 450 W AC | Bronze 50/60 Hz 100 240 V AC, auto-arranging |
Temperature | Specifications |
Storage | 40°C to 65°C (40°F to 149°F) |
Continuous operation (for altitude less than 950 m or 3117 ft) | 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. |
Fresh air | |
Maximum temperature gradient (operating and storage) | 20°C/h (68°F/h) |
Relative Humidity | Specifications |
Storage | 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times. |
Operating | 10% to 80% relative humidity with 29°C (84.2°F) maximum dew point. |
Maximum Vibration | Specifications |
Operating | 0.26 Grms at 5 Hz to 350 Hz (all operation orientations). |
Storage | 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested). |
Maximum Shock | Specifications |
Operating | Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 6 G for up to 11 ms. |
Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms. |
Maximum Altitude | Specifications |
Operating | 3048 m (10,000 ft) |
Storage | 12,000 m (39,370 ft) |
Standard Operating Temperature | Specifications |
Continuous operation (for altitude less than 950 m or 3117 ft). | 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. |
Expanded Operating Temperature | Specifications |
Continuous operation | 5°C to 40°C at 5% to 85% RH with 29°C dew point.
Note: Outside the standard operating temperature (10°C to 40°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C.
|
1% of annual operating hours | -5°C to 45°C at 5% to 90% RH with 29°C dew point.
Note: Outside the standard operating temperature (10°C to 40°C), the system can operate down to -5°C or up to 45°C for a maximum of 1% of its annual operating hours.
For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft). |
- Do not perform a cold startup below 5°C.
- The operating temperature specified is for a maximum altitude of 3048 m (10,000 ft).
- 105 W/4C, 115 W/6C, 130 W/8C, 140 W/14C or higher wattage processor (TDP>140 W) are not supported.
- Redundant power supply configuration is required.
- Non-Arista qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
- NVMe drives are not supported.
- Apache Pass DIMM and NVDIMM are not supported.
Operating temperature derating | Specifications |
Up to 35°C (95°F) | Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft). |
35°C to 40°C (95°F to 104°F) | Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft). |
40°C to 45°C (104°F to 113°F) | Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft). |