Maintenance and Field Replacement
The following topics are covered in this section:
Considerations
- All fans and power supplies are hot swappable.
- The switch can be running while a power supply is being installed or removed, but the power supply being replaced must not be connected to a power source.
- All slots must be filled or covered with a blank for operation (even though power supply or fans may not be functional).
- Replacement parts should be the same or compatible with those being replaced.
- Before you begin, refer to the Arista Networks document Safety Information and Translated Safety Warnings available at: https://www.arista.com/en/support/product-documentation.
Note: Refer to the front (Front Panel) and rear (Rear Panel) panel illustrations of your device to locate the appropriate LED, the release lever or handle, and the handle for the power supply and fan modules.
Power Supplies
The following steps are required when removing power supplies from a switch:
Removing a Power Supply
- Ground yourself with an ESD wrist strap.
- Power down the power supply to be removed by disconnecting the AC power cable.
- Push the power supply release lever and remove the power supply.
Installing a Power Supply
You must make space for installing the power supply by removing an existing one (Removing a Power Supply).
Fan Modules
Note: Hot swap fans within 30 seconds to prevent the switch from overheating. Ensure that the module you are replacing matches those already installed in the switch.
Removing a Fan Module
- Ground yourself with an ESD wrist strap.