Overview

This guide is intended for network or security professionals and technicians who need to install the required Arista 720D Series Ethernet Switch.

The following topics are covered in this section:

Scope

This section lists the devices that are described in this guide:

Important: Only qualified personnel should install, service, or replace this equipment.

Seul le personnel qualifié doit installer, service, ou remplacer cet équipement.

  • CCS-720DP-48S-2F

  • CCS-720DP-48S-M-S-2F

  • CCS-720DP-24S-2F

  • CCS-720DP-24S-M-S-2F

  • CCS-720DT-48S-2F

  • CCS-720DT-48S-2R

  • CCS-720DT-24S-2F

  • CCS-720DT-24S-M-S-2F

  • CCS-720DT-24S-2R

  • CCS-720DF-48Y-2F

  • CCS-720DF-48Y-M-S-2F

  • CCS-720DF-48Y-DC-2F

  • CCS-720DP-24ZS-2F

  • CCS-720DP-48ZS-2F

Receiving and Inspecting the Equipment

 

Upon receiving the device, inspect the shipping boxes and record if there is any external damage. Retain the packing equipment if you suspect any part of the shipment is damaged; the carrier might need it inspected.

If the boxes were not damaged during transit, unpack them carefully. Do not discard any accessories that may have been packed in the same box as the switch.

Inspect the packing list and confirm that you received all the items listed. Compare the packing list with your purchase order. The Parts List section provides a list of components included with the device.

Installation Process

This section describes the steps required to install the switch:

Important: Class 1 Laser Product: This product has provisions for installing Class 1 laser transceivers that provide optical coupling to the communication network. Once a Class 1 1 laser product is installed, the equipment is a Class 1 Laser Product. The customer is responsible for selecting and installing the Class 1 laser transceiver and for ensuring that the Class 1 AEL (Allowable Emission Limit) per EN/IEC 60825, CSA E60825-1, and Code of Federal Regulations 21 CFR 1040 is not exceeded after the laser transceiver have been installed. Do not install laser products whose class rating is greater than 1. Refer to all safety instructions that accompany the transceiver before installation. Only Class 1 laser devices certified for use in the country of installation by the cognizant agency are to be utilized in this product.

Produit Laser de classe 1: Ce produit a des dispositions pour installer des émetteursrécepteurs de laser de classe 1 qui offre de couplage au réseau de communication optique.Une fois un produit laser de classe 1 est installé, l'équipement est un produit Laser de classe 1 (Appareil à Laser de Classe 1).Le client est responsable pour sélectionner et installer l'émetteur/récepteur de laser de classe 1 et pour assurer que la classe 1 AEL (limite d'émission admissible) par EN/IEC 60825, CSA E60825-1, et Code des règlements fédéraux 21 CFR 1040 ne soit pas dépassée après avoir installé l'émetteur/récepteur de laser. Ne pas installer des appareils à laser dont la cote de classe est supérieure à 1.Voir toutes les consignes de sécurité qui ont accompagné l'émetteur-récepteur avant l'installation. Seuls appareils laser de classe 1 certifiés pour une utilisation dans le pays d’installation par l’organisme compétent doivent être utilisées dans ce produit.

Important: Ultimate disposal of this product should be in accordance with national laws and regulations.

Aucune pièce réparable par l'utilisateur à l'intérieur. Confiez toute réparation à un technicien qualifié.

The following steps are to be followed to install the switch:

  1. Select the installation site. (Site Selection)
  2. Assemble the installation tools listed. (Tools and Parts Required for Installation)
  3. Attach the mounting brackets and install the switch in an equipment rack. (Rack Mounting the Switch)
  4. Connect the switch to the power source and network devices. (Cabling the Switch)
  5. Configure the switch. (Configuring the Switch)

Obtaining Technical Assistance

Any customer, partner, reseller, or distributor holding a valid Arista Service Contract can obtain technical support in any of the following ways:

  • Email: 이 이메일 주소가 스팸봇으로부터 보호됩니다. 확인하려면 자바스크립트 활성화가 필요합니다.

    Include a detailed description of the problem and the “show tech-support” output.

  • Web: https://www.arista.com/en/support

    A support case may be created through the support portal on our website. You may also download the most recent software and documentation, and view FAQs, Knowledge Base articles, Security Advisories, and Field Notices.

  • Phone: +1 866-476-0000 or +1 408-547-5502.

Specifications

This section lists the specifications of the Arista Ethernet Switches described in this guide.

Table 1. Ethernet Switch Specifications (Dimensions and Weights)

Device

Size (W x H x D)

Weight

CCS-720DP-48S-2F

440 x 43.5 x 430 mm

(17.32 x 1.71 x 16.92 inches)

6.73 kg

(14.83 lbs)

CCS-720DP-24S-2F

440 x 43.5 x 330 mm

(17.32 x 1.71 x 12.99 inches)

5.81 kg

(12.80 lbs)

CCS-720DT-48S-2F

440 x 43.5 x 330 mm

(17.32 x 1.71 x 12.99 inches)

4.638 kg

(10.22 lbs)

CCS-720DT-48S-2R

440 x 43.5 x 330 mm

(17.32 x 1.71 x 12.99 inches)

4.638 kg

(10.22 lbs)

CCS-720DT-24S-2F

440 x 43.5 x 330 mm

(17.32 x 1.71 x 12.99 inches)

4.356 kg

(9.60 lbs)

CCS-720DT-24S-2R

440 x 43.5 x 330 mm

(17.32 x 1.71 x 12.99 inches)

4.356 kg

(9.60 lbs)

CCS-720DF-48Y-2F

440 x 43.5 x 330 mm

(17.32 x 1.71 x 12.99 inches)

4.8 kg

(10.58 lbs)

CCS-720DF-48Y-DC-2F

440 x 43.5 x 330 mm

(17.32 x 1.71 x 12.99 inches)

4.77 kg

(10.51 lbs)

CCS-720DP-24ZS-2F

440 x 43.5 x 430 mm

(17.32 x 1.71 x 16.92 inches)

6.6 kg

(14.55 lbs)

CCS-720DP-48ZS-2F

440 x 43.5 x 430 mm

(17.32 x 1.71 x 16.92 inches)

8 kg

(17.63 lbs)

CCS-720DF-48Y-M-S-2F

440 x 43.5 x 330 mm

(17.32 x 1.71 x 12.99 inches)

4.5 kg

(9.92 lbs)

CCS-720DP-48S-M-S-2F

440 x 43.5 x 430 mm

(17.32 x 1.71 x 16.92 inches)

6.73 kg

(14.83 lbs)

CCS-720DP-24S-M-S-2F

440 x 43.5 x 330 mm

(17.32 x 1.71 x 12.99 inches)

5.81 kg

(12.80 lbs)

CCS-720DT-24S-M-S-2F

440 x 43.5 x 330 mm

(17.32 x 1.71 x 12.99 inches)

4.356 kg

(9.60 lbs)

Table 2. Ethernet Switch Specifications (Operational and Storage)

Device

Operating Temperature

Storage Temperature

Operating Altitude

Relative Humidity

CCS-720DP-48S

0 to 40°C

(32° to 104°F)

-25 to 70°C

(-13 to 158F)

0 to 3,000 meters

(0 to 10,000 feet)

5 to 90%

(non-condensing)

CCS-720DT-48S

0 to 40°C

(32° to 104°F)

-25 to 70°C

(-13 to 158F)

0 to 3,000 meters

(0 to 10,000 feet)

5 to 90%

(non-condensing)

CCS-720DP-24S

0 to 40°C

(32° to 104°F)

-25 to 70°C

(-13 to 158F)

0 to 3,000 meters

(0 to 10,000 feet)

5 to 90%

(non-condensing)

CCS-720DT-24S

0 to 40°C

(32° to 104°F)

-25 to 70°C

(-13 to 158F)

0 to 3,000 meters

(0 to 10,000 feet)

5 to 90%

(non-condensing)

CCS-720DF-48Y

0 to 40°C

(32° to 104°F)

-25 to 70°C

(-13 to 158F)

0 to 3,000 meters

(0 to 10,000 feet)

5 to 90%

(non-condensing)

CCS-720DF-48Y-DC

0 to 40°C

(32° to 104°F)

-25 to 70°C

(-13 to 158F)

0 to 3,000 meters

(0 to 10,000 feet)

5 to 90%

(non-condensing)

CCS-720DP-24ZS

0 to 40°C

(32° to 104°F)

-25 to 70°C

(-13 to 158F)

0 to 3,000 meters

(0 to 10,000 feet)

5 to 90%

(non-condensing)

CCS-720DP-48ZS

0 to 40°C

(32° to 104°F)

-25 to 70°C

(-13 to 158F)

0 to 3,000 meters

(0 to 10,000 feet)

5 to 90%

(non-condensing)

Table 3. Ethernet Switch Specifications (Power Ratings)

Device

Input Power Rating

CCS-720DP-48S-2F

100 - 240V~, 10 - 5A, 50/60 Hz

CCS-720DP-48S-M-S-2F

100 - 240V~, 10 - 5A, 50/60 Hz

CCS-720DP-24S-2F

100 - 240V~, 6 - 3A, 50/60 Hz

CCS-720DP-24S-M-S-2F

100 - 240V~, 6 - 3A, 50/60 Hz

CCS-720DT-48S-2F

100 - 240V~, 1.2-0.6A, 50/60 Hz

CCS-720DT-48S-2R

100 - 240V~, 1.2-0.6A, 50/60 Hz

CCS-720DT-24S-2F

100 - 240V~, 1-0.5A, 50/60 Hz

CCS-720DT-24S-M-S-2F

100 - 240V~, 1-0.5A, 50/60 Hz

CCS-720DT-24S-2R

100 - 240V~, 1-0.5A, 50/60 Hz

CCS-720DF-48Y-2F

100 - 240V~, 2.2-1.1A, 50/60 Hz

CCS-720DF-48Y-M-S-2F

100 - 240V~, 2.2-1.1A, 50/60 Hz

CCS-720DF-48Y-DC-2F

-48 to -60VDC, 4.5-3.6A

CCS-720DP-24ZS-2F

100 - 240V~, 10-5A, 50/60 Hz

CCS-720DP-48ZS-2F

100 - 240V~, 10A, 50/60 Hz

Table 4. Ethernet Switch Specifications (PoE Power Budget)

Device

PoE Power Budget

CCS-720DP-48S

745W

CCS-720DT-48S

N/A

CCS-720DP-24S

380W

CCS-720DT-24S

N/A

CCS-720DF-48Y

N/A

CCS-720DF-48Y-DC

N/A

CCS-720DP-24ZS

730W

CCS-720DP-48ZS

120V: 2x700W

240V: 2x1440W

CCS-720DP-48ZS

120V: 700W

240V: 1500W

Table 5. Ethernet Switch Specifications (System Configurations)

Device

PoE Ports

Downlink Ports

Uplink Ports

Airflow

Power Supply

Fan

CCS-720DP-48S-2F

30W

48x1G RJ45

4x10G SFP+

Front to rear

2

4

CCS-720DP-48S-M-S-2F

30W

48x1G RJ45

4x10G SFP+

Front to rear

2

4

CCS-720DP-24S-2F

30W

24x1G RJ45

4x10G SFP+

Front to rear

2

3

CCS-720DP-24S-M-S-2F

30W

24x1G RJ45

4x10G SFP+

Front to rear

2

3

CCS-720DT-48S-2F

N/A

48x1G RJ45

4x10G SFP+

Front to rear

2

2

CCS-720DT-48S-2R

N/A

48x1G RJ45

4x10G SFP+

Rear to Front

2

2

CCS-720DT-24S-2F

N/A

24x1G RJ45

4x10G SFP+

Front to rear

2

2

CCS-720DT-24S-M-S-2F

N/A

24x1G RJ45

4x10G SFP+

Front to rear

2

2

CCS-720DT-24S-2R

N/A

24x1G RJ45

4x10G SFP+

Rear to front

2

2

CCS-720DF-48Y-2F

N/A

48x1G SFP

4x25G SFP28

Front to rear

2

3

CCS-720DF-48Y-M-S-2F

N/A

48x1G SFP

4x25G SFP28

Front to rear

2

3

CCS-720DF-48Y-DC-2F

N/A

48x1G SFP

4x25G SFP28

Front to rear

2

3

CCS-720DP-24ZS-2F

60W

24x2.5G RJ45

4x10G SFP+

Front to rear

2

4

CCS-720DP-48ZS-2F

60W

48x2.5G RJ45

4x10G SFP+

Front to rear

2