Overview

This guide is for properly trained service personnel and technicians who need to install selected Arista Networks Data Center Switches.

Scope

This guide covers the following devices:

1RU Switches
DCS-7130LBR-48S6QD DCS-7132LB-48Y4C DCS-7135LB-48Y4C  
2RU Switches
DCS-7130B-32QD DCS-7130B-32YD    
Important: Only qualified or trained personnel should install, service, or replace this equipment.

 

Seul le personnel qualifié doit installer, service, ou remplacer cet équipement.

Receiving and Inspecting the Equipment

Upon receiving the switch, inspect the shipping boxes and record any external damage. Retain packing materials if you suspect that part of the shipment is damaged; the carrier may need to inspect them.

If the boxes were not damaged in transit, unpack them carefully. Assure that you do not discard any accessories packaged in the same box as the main unit.

Inspect the packing list and confirm that you received all listed items. Compare the packing list with your purchase order. Parts List provides a list of components included with the switch.

Safety Information

Refer to the Arista Networks document Safety Information and Translated Safety Warnings: https://www.arista.com/en/support/product-documentation.

Important:

Class 1 Laser Product: This product has provisions for installing Class 1 laser transceivers that provide optical coupling to the communication network. After installing a Class 1 laser product, the equipment is a Class 1 Laser Product. The customer is responsible for selecting and installing the Class 1 laser transceiver and not exceeding the Class 1 AEL (Allowable Emission Limit) per EN/IEC 60825, CSA E60825-1, and Code of Federal Regulations 21 CFR 1040 after installing the laser transceiver. Do not install laser products whose class rating is greater than 1. Refer to all safety instructions that accompany the transceiver before installation. Only Class 1 laser devices, certified for use in the country of installation by the cognizant agency, are to be utilized in this product. The ultimate disposal of this product should be by all applicable laws and regulations.

 

Produit Laser de classe 1: Ce produit a des dispositions pour installer des émetteurs-récepteurs de laser de classe 1 qui offre de couplage au réseau de communication optique.Une fois un produit laser de classe 1 est installé, l'équipement est un produit Laser de classe 1 (Appareil à Laser de Classe 1).Le client est responsable pour sélectionner et installer l'émetteur/récepteur de laser de classe 1 et pour assurer que la classe 1 AEL (limite d'émission admissible) par EN/IEC 6-825, CSA E60825-1, et Code des règlements fédéraux 21 CFR 1040 ne soit pas dépassée après avoir installé l'émetteur/récepteur de laser. Ne pas installer des appareils à laser dont la cote de classe est supérieure à 1.Voir toutes les consignes de sécurité qui ont accompagné l'émetteur-récepteur avant l'installation. Seuls appareils laser de classe 1 certifiés pour une utilisation dans le pays d’installation par l’organisme compétent doivent être utilisées dans ce produit. L'élimination finale de ce produit doit être effectuée conformément à toutes les lois nationales etrèglements.

 

Important:

DO NOT open the router case. There are NO user-serviceable parts inside. Entrust any repair to a qualified technician.

 

N’ouvrez PAS le boîtier du routeur. Il n’y a AUCUNE pièce réparable par l’utilisateur à l’intérieur. Confiez toute réparation à un technicien qualifié.

Obtaining Technical Assistance

Any customer, partner, reseller, or distributor holding a valid Arista Service Contract can obtain technical support in the following ways.

Specifications

This guide covers a list of specifications for the Arista 713x data center modular switches and components.

Table 1. Switch Specifications (Dimensions and Weights)
Switch Size (W x H x D) Weight
DCS-713x Series switches (1RU)
DCS-7130LBR-48S6QD 48.3 x 4.4 x 65.8 cm (19 x 1.75

x 25.9 inches)

14.8 kg (32.6 lbs.)
DCS-7132LB-48Y4C 48.3 x 4.4 x 47.3 cm

(19 x 1.75 x 18.6 inches)

9.8 kg (21.6 lbs.)
DCS-7135LB-48Y4C 48.3 x 4.4 x 57.0 cm

(19 x 1.75 x 22.4 inches)

12.2 kg (26.8 lbs.)
DCS-713x Series switches (2RU)
DCS-7130B-32QD 48.3 x 8.8 x 76.2 cm

(19 x 3.50 x 30.0 inches)

22.5 kg (49.6 lbs.)
DCS-7130B-32YD 48.3 x 8.8 x 76.2 cm

(19 x 3.50 x 30.0 inches)

22.5 kg (49.6 lbs.)

 

Table 2. Switch Specifications (Operational and Storage)
Switch Operating Temperature Storage Temperature Operating Altitude Relative Humidity
All 0° to 40°C (32° to 104°F) -25° to 70°C (-13° to 158°F) 0 to 3,000 meters (0 to 10,000 feet) 5 to 90% (non-condensing)

 

Table 3. Switch Specifications (Power Input)
Power Source PSU Models Ratings
Power Input: AC
  PWR-1011-AC 100 - 120 / 200 - 240 VAC 12 / 6 A 50/60 Hz
  PWR-1511-AC 200 - 240 VAC 9.6 A 50/60 Hz
  PWR-1512-AC 200 - 240 VAC 9.6 A 50/60 Hz
  PWR-2411-AC 200 - 240 VAC 14 A 50/60 Hz
Power Input: DC
  PWR-1011-DC -48 to -60 VDC, 30 A
  PWR-1511-DC -48 to -60 VDC, 38 A
  PWR-2411-DC -48 to -60 VDC, 55 A
Note: Use only the PSU models supported by the switch. Some switches described in this guide could use power supplies that may no longer be available. Contact your local Arista representative for more information.

 

Table 4. Switch Specifications (Power Draw)
Switch Power Draw (Typical / Maximum) Supported Power Supply
DCS-713X Series switches (1RU)
DCS-7130LBR-48S6QD 391 W / 650 W PWR-1511-AC, PWR-1512-AC, PWR-1511-DC
DCS-7132LB-48Y4C 367 W / 550 W PWR-1011-AC, PWR-1011-DC
DCS-7135LB-48Y4C 667 W / 1000 W PWR-1511-AC, PWR-1512-AC, PWR-1511-DC
DCS-713X Series switches (2RU)
DCS-7130B-32QD 618 W / 1124 W PWR-2411-AC, PWR-2411-DC